淺(qian)談(tan)基於無線網絡的高(gao)校(xiao)宿(xiu)舍用(yong)電(dian)管(guan)理(li)系(xi)統設計(ji)及(ji)產品應用(yong)方案
安(an)科瑞電(dian)氣股份有(you)限(xian)公(gong)司 上(shang)海嘉(jia)定 201801
摘要:設計(ji)了(le)壹種基於無線網絡的用(yong)電(dian)管(guan)理(li)系(xi)統,主要(yao)包括現(xian)場(chang)控(kong)制櫃、售電(dian)處(chu)與(yu)管(guan)理(li)軟件(jian)、數據服務器,網關節(jie)點等(deng)。通(tong)過(guo)在控(kong)制櫃上(shang)安裝(zhuang)RS485接口(kou)與電表連接(jie),采(cai)集電表數據(ju),然後通(tong)過(guo)無線網絡將電(dian)表數據(ju)發(fa)送(song)給(gei)網關,終(zhong)上(shang)傳給(gei)數據(ju)服務器。實現(xian)了(le)節(jie)能(neng)辦的(de)管(guan)理(li)系(xi)統通過(guo)校(xiao)園網訪問任(ren)意(yi)的現(xian)場操(cao)作站(zhan),從而(er)可以(yi)對(dui)某(mou)塊電(dian)表進行(xing)遠程設置,並(bing)讀取(qu)電表的實時數據(ju),同(tong)時學生(sheng)可以(yi)通(tong)過(guo)網絡查(zha)詢(xun)宿(xiu)舍用(yong)電(dian)量(liang),重(zhong)點介(jie)紹(shao)控(kong)制櫃與(yu)網關的軟硬(ying)件設計(ji)。
關(guan)鍵詞(ci):無線傳輸;用(yong)電(dian)管(guan)理(li)系(xi)統;網關;控(kong)制櫃節(jie)點
0引(yin)言(yan)
在目(mu)前的高(gao)校(xiao)用(yong)電(dian)管(guan)理(li)工(gong)作中(zhong),如(ru)何(he)建(jian)立學生(sheng)的主(zhu)動節(jie)能(neng)意(yi)識和如(ru)何(he)確(que)保學生(sheng)的用(yong)電(dian)安(an)全(quan)是(shi)2個不容忽(hu)視(shi)的(de)問(wen)題。
為(wei)了減(jian)少(shao)這(zhe)種(zhong)問題發(fa)生(sheng)的幾(ji)率(lv),許多(duo)學校(xiao)推廣(guang)和使用(yong)了(le)預(yu)付費(fei)電表。這(zhe)種(zhong)電表是讓(rang)學生(sheng)的用(yong)電(dian)量(liang)在(zai)超(chao)出(chu)了範(fan)圍之(zhi)後,對(dui)於超(chao)出(chu)的部(bu)分要(yao)自行(xing)買(mai)單(dan),這(zhe)在(zai)很(hen)大(da)程度上(shang)提高(gao)了學生(sheng)的節(jie)能(neng)意(yi)識,並(bing)且(qie)在電(dian)表中(zhong)增加(jia)了(le)對(dui)電(dian)流和惡(e)性負載(zai)的控(kong)制,可以(yi)有(you)效(xiao)地避(bi)免由(you)於不安全(quan)用(yong)電(dian)引(yin)發(fa)的(de)事(shi)故(gu)。
但(dan)是目(mu)前在高(gao)校(xiao)中(zhong),並(bing)沒(mei)有(you)形(xing)成(cheng)壹整(zheng)套(tao)完整(zheng)的用(yong)電(dian)管(guan)理(li)系(xi)統。基於此,本(ben)文設計(ji)了(le)1套(tao)基於無線網絡的用(yong)電(dian)管(guan)理(li)系(xi)統。本系(xi)統具有實時性、安全(quan)性、易管理(li)性等特點。
1系(xi)統硬(ying)件組成
系(xi)統的硬(ying)件組成如(ru)圖1所示。從圖1中(zhong)可以(yi)看(kan)出(chu),節(jie)能(neng)辦通(tong)過(guo)內部(bu)網絡將數(shu)據上(shang)傳到(dao)數據(ju)服務器,通過(guo)服務代理(li)從物理(li)上(shang)與外網隔離。售電(dian)終(zhong)端對(dui)數據(ju)進行(xing)加(jia)密之(zhi)後通(tong)過(guo)互聯網上(shang)傳給(gei)數據(ju)服務器,以(yi)確(que)保(bao)數據(ju)的安(an)全(quan)性。節(jie)點作為(wei)網關的無線網卡(ka)接(jie)收(shou)現場控(kong)制櫃發(fa)送(song)來(lai)的(de)數(shu)據(ju),然後上(shang)傳給(gei)數據(ju)服務器[2]。宿(xiu)舍管(guan)理(li)員在網絡故(gu)障的(de)時候可以(yi)通(tong)過(guo)現場(chang)控(kong)制櫃完(wan)成(cheng)必需的操(cao)作。學生(sheng)可以(yi)在(zai)網上(shang)通過(guo)瀏(liu)覽(lan)器查(zha)詢(xun)本(ben)宿(xiu)舍用(yong)電(dian)明細(xi)。
1.1現場(chang)控(kong)制櫃
現(xian)場(chang)控(kong)制櫃是(shi)保(bao)證(zheng)正(zheng)常(chang)供(gong)電(dian)的(de)核(he)心(xin),因此,現(xian)場控(kong)制櫃的(de)長(chang)期(qi)、穩定的(de)運(yun)行(xing)對(dui)系(xi)統的正(zheng)常(chang)工(gong)作有(you)著決定性的意(yi)義(yi)。
本(ben)系(xi)統中(zhong)控(kong)制櫃安(an)裝(zhuang)在宿(xiu)舍樓。硬(ying)件采(cai)用(yong)ARM7處(chu)理(li)器,它(ta)體(ti)積小、集成度高(gao)、實時性高(gao)。控(kong)制櫃內安(an)裝(zhuang)了(le)嵌人(ren)式(shi)硬(ying)件,配(pei)有(you)觸(chu)摸鍵盤(pan)和液晶(jing)顯(xian)示單(dan)元(yuan),電(dian)表和控(kong)制櫃之(zhi)間(jian)通過(guo)RS485端口(kou)傳輸數據,采(cai)用(yong)屏(ping)蔽(bi)雙絞(jiao)線(xian)作為(wei)傳輸(shu)介質(zhi),總(zong)線型(xing)連接(jie)。每(mei)個控(kong)制櫃可以(yi)采(cai)集30塊電表的數(shu)據(ju),傳輸速(su)率(lv)設定為(wei)4800bps。同(tong)時通過(guo)無線網絡和數據(ju)連(lian)接。控(kong)制櫃硬(ying)件設計(ji)如(ru)圖2所示。


1.2網關與節(jie)點
網關與節(jie)點的(de)主(zhu)要(yao)工(gong)作是(shi)在接收(shou)到控(kong)制櫃節(jie)點發(fa)來(lai)的(de)數(shu)據(ju)時,將數(shu)據轉(zhuan)換(huan)成(cheng)與(yu)互聯網數據包格式相(xiang)同(tong)的(de)數(shu)據包上(shang)傳給(gei)數據(ju)服務器存儲(chu);在(zai)接收(shou)到客戶(hu)端(duan)發(fa)來(lai)的(de)命(ming)令時,執(zhi)行(xing)相(xiang)應的(de)工(gong)作。網關與控(kong)制櫃節(jie)點之(zhi)間(jian)的結(jie)構(gou)如(ru)圖3所示。

在圖3中(zhong),HTTPClient代表客戶(hu)端(duan),可以(yi)是(shi)學生(sheng)在宿(xiu)舍查(zha)詢(xun)用(yong)電(dian)量(liang)使用(yong)的(de)瀏(liu)覽(lan)器,也可以(yi)是(shi)節(jie)能(neng)辦人(ren)員(yuan)統計、修改宿(xiu)舍電(dian)量的客戶(hu)端(duan)。HTTP/CoAP代表網關,網關的功(gong)能是執(zhi)行(xing)協(xie)議間(jian)的轉換。網關與控(kong)制櫃節(jie)點之(zhi)間(jian)使用(yong)星(xing)形(xing)網絡拓(tuo)撲(pu)結(jie)構(gou)。將(jiang)節(jie)點作為(wei)協調(tiao)器,只存(cun)在(zai)協調器與控(kong)制櫃節(jie)點之(zhi)間(jian)的通信,控(kong)制櫃節(jie)點相(xiang)互(hu)之(zhi)間(jian)的通信通(tong)過(guo)協調(tiao)器轉發(fa)。
網關采(cai)用(yong)ARM7處(chu)理(li)器,網關與Internet的(de)連接通過(guo)以(yi)太網口,與控(kong)制櫃的(de)連(lian)接通過(guo)無線。硬(ying)件結(jie)構(gou)如(ru)圖4所示。

2系(xi)統軟件(jian)組成
該(gai)系(xi)統的軟件(jian)由4部(bu)分組成,分(fen)別(bie)是(shi)數據管理(li)軟件(jian)、售電(dian)軟件(jian)、現場控(kong)制櫃軟件(jian)和基於IEEE802.15.4無線網絡的網絡協議棧(zhan)。
2.1現場(chang)控(kong)制櫃
本(ben)系(xi)統使用(yong)了(le)嵌入(ru)式(shi)Linux系(xi)統(embeddedLinux),嵌入(ru)式(shi)操(cao)作系(xi)統負責(ze)嵌入(ru)式(shi)系(xi)統的全(quan)部(bu)軟、硬(ying)件資(zi)源的分(fen)配(pei)、調(tiao)度(du)工(gong)作,控(kong)制並(bing)協調(tiao)並(bing)發(fa)活(huo)動,能夠通過(guo)裝卸(xie)某些模塊來(lai)達(da)到(dao)系(xi)統所要求的(de)功(gong)能。經過(guo)內核(he)裁(cai)剪,將系(xi)統移植(zhi)到(dao)開發(fa)板(ban)上(shang),不需要(yao)硬(ying)盤作為(wei)存儲(chu)介質(zhi),也(ye)不需要(yao)鍵盤(pan)、鼠標(biao)等外設。
控(kong)制櫃節(jie)點的(de)主(zhu)要(yao)功(gong)能是采(cai)集和發(fa)送(song)電(dian)表數據(ju)。控(kong)制櫃和電表之(zhi)間(jian)的數據傳(chuan)輸(shu)通過(guo)RS485接口(kou),數據傳輸遵循電力(li)行(xing)業(ye)標準(zhun)《DL/T645—1997645多(duo)功能(neng)電能(neng)表通信(xin)規約(yue)》(Multi-functionwatt-hourmetercommunicationprotocol)。與電表交互(hu)的(de)數據(ju)如(ru)表1所示。
表1控(kong)制櫃和電表交互(hu)數(shu)表
序(xu)號(hao) | 數(shu)據(ju)內容(rong) | 方式 | 數據代碼 |
2 | 斷電(dian)次(ci)數 實時電流(liu) | 讀/寫(xie) 讀 | B310 B620 |
3 | 實時功率(lv) | 讀 | B630 |
4 | 日(ri)期(qi) | 讀/寫(xie) | CO11 |
5 | 時間(jian) | 讀/寫(xie) | C010 |
控(kong)制櫃節(jie)點與(yu)網關的數(shu)據傳輸是通過(guo)無線。控(kong)制櫃節(jie)點協(xie)議棧(zhan)的軟件(jian)組成如(ru)圖5所示。
應用(yong)層的CoAP協議是適用(yong)於受(shou)限(xian)設備(bei)的(de)協(xie)議,它(ta)可以(yi)說(shuo)是HTTP協(xie)議的1個子集,CoAP協議所構(gou)造(zao)的(de)數據包小的(de)只有2個字(zi)節(jie),非(fei)常適(shi)合低(di)功(gong)耗(hao)的無線傳輸需(xu)求[4];在(zai)傳(chuan)輸層,由於不需要(yao)保(bao)證(zheng)數(shu)據(ju)包的準(zhun)確性,所以(yi)采(cai)用(yong)了(le)UDP協(xie)議;為(wei)了滿足控(kong)制櫃節(jie)點對(dui)地(di)址(zhi)的(de)需求,在(zai)本(ben)設計(ji)中(zhong)為(wei)每1個控(kong)制櫃節(jie)點配(pei)備(bei)1個IPv6地址(zhi);但(dan)是由(you)於802.15.4傳(chuan)輸(shu)的數(shu)據長度有限(xian),為(wei)了提(ti)高(gao)傳輸(shu)效率(lv),在物理(li)層與IP層之(zhi)間(jian)加(jia)入(ru)壓(ya)縮(suo)IPv6數(shu)據(ju)包的6LoWPAN層,在這(zhe)1層使用(yong)LoWPAN_IPHC算(suan)法對IPv6數據包進行(xing)壓(ya)縮(suo)[5-]。控(kong)制櫃的(de)無線接收(shou)發(fa)送(song)數(shu)據(ju)包的軟件(jian)流程如(ru)圖6所示。


控(kong)制櫃在(zai)接(jie)收(shou)到CoAP請(qing)求之(zhi)後,首(shou)先對請(qing)求進(jin)行(xing)解(jie)析(xi),得(de)到(dao)數據包中(zhong)的option項內容(rong),從而(er)根(gen)據(ju)option來(lai)查(zha)找(zhao)所請(qing)求的(de)資(zi)源。如(ru)果找(zhao)到(dao),則(ze)構(gou)造(zao)回(hui)復數(shu)據包,將資(zi)源放入(ru)payload項,送給(gei)UDP/IPv6層。否(fou)則(ze)發(fa)送(song)錯(cuo)誤信(xin)息(xi)數(shu)據包給UDP/IPv6層。在UDP/IPv6層,數據包被添加(jia)上(shang)目的(de)地址(zhi)等信息(xi)送(song)給6LoWPAN層。在6LoWPAN層通過(guo)LoWPAN_IPHC算法對數據包進行(xing)壓(ya)縮(suo),根(gen)據(ju)IPv6地(di)址與MAC地址的(de)關(guan)聯對(dui)地(di)址(zhi)進(jin)行(xing)壓(ya)縮(suo),並(bing)有條件的(de)省略(lve)掉(diao)流控(kong)制等多(duo)余的項,從而(er)降低(di)數(shu)據(ju)包的大(da)小來(lai)達(da)到(dao)提(ti)高(gao)了傳(chuan)輸效(xiao)率(lv)的目的[8-10]。
2.2網關
網關上(shang)運行(xing)Linux系(xi)統,將節(jie)點作為(wei)無線網卡(ka)連(lian)接到網關。網關協議棧(zhan)的軟件(jian)結(jie)構(gou)如(ru)圖7所示。

由於客(ke)戶(hu)端(duan)使用(yong)HTTP協(xie)議,而(er)控(kong)制櫃節(jie)點使用(yong)CoAP協(xie)議,所以(yi)網關的主(zhu)要功能是協議的轉換,其軟件(jian)流程如(ru)圖8所示。

網關在接(jie)收(shou)到HTTP客戶(hu)端(duan)的(de)請(qing)求之(zhi)後,首(shou)先對數(shu)據包進行(xing)解(jie)析(xi),根據CoAP與(yu)HTTP的對應關(guan)系(xi)判斷(duan)能否(fou)轉(zhuan)換成CoAP數(shu)據包。如(ru)果不可以(yi),則(ze)發(fa)送(song)錯(cuo)誤報(bao)告(gao)給(gei)客(ke)戶(hu)端(duan)。轉(zhuan)換後的(de)數據包由socket接(jie)口(kou)傳(chuan)送給(gei)MAC層,然後通(tong)過(guo)無線發(fa)送(song),並(bing)打(da)開計(ji)時器。如(ru)果在定時器溢出(chu)之(zhi)內收(shou)到回(hui)復,則(ze)解析(xi)回(hui)復數(shu)據包,並(bing)轉換(huan)成HTTP格式,返(fan)回(hui)給客(ke)戶(hu)端(duan)。否(fou)則(ze)回(hui)復“超(chao)時"的數(shu)據包給客(ke)戶(hu)端(duan)。
3智(zhi)能水(shui)、電表的管(guan)理(li)
3.1系(xi)統管理(li)平(ping)臺(tai)
IOT智(zhi)能水(shui)電表管理(li)系(xi)統是通(tong)過(guo)IOTP(InternetOpenTradingProtocol,網絡開放(fang)貿(mao)易(yi)協(xie)議)來(lai)讀取(qu)水、電表定時上(shang)報的(de)電量(liang)信息(xi),向(xiang)電表發(fa)送(song)合閘/拉閘的(de)命(ming)令,返(fan)回(hui)其狀態值(zhi)。
智(zhi)能水(shui)、電表系(xi)統後臺(tai)管(guan)理(li)界面如(ru)圖3所示。

系(xi)統後臺(tai)可以(yi)實時監(jian)測每個接入(ru)商(shang)戶(hu)的(de)即(ji)時賬戶(hu)余額、合同(tong)有(you)效(xiao)期(qi)、費(fei)率(lv)、,以(yi)及(ji)各商戶(hu)名下的水(shui)電(dian)表安裝(zhuang)位置、各自用(yong)量(liang)等(deng)信(xin)息(xi)。為(wei)了簡(jian)化(hua)結(jie)算(suan)流程,本(ben)文(wen)設計(ji)將(jiang)水(shui)電表的用(yong)量(liang)以(yi)商(shang)戶(hu)為(wei)單(dan)位進行(xing)匯總統-結(jie)算(suan)。
3.2商戶(hu)費(fei)用(yong)查(zha)詢(xun)及(ji)繳納(na)
商(shang)戶(hu)余額查(zha)詢(xun):商(shang)戶(hu)可以(yi)登(deng)陸(lu)web頁面或(huo)者(zhe)通過(guo)學校(xiao)微信(xin)服(fu)務號綁(bang)定其(qi)壹卡(ka)通(tong)賬號(hao),實現(xian)線(xian)上(shang)自助(zhu)查(zha)詢(xun)。壹卡(ka)通(tong)管理(li)平(ping)臺(tai)通(tong)過(guo)調用(yong)用(yong)電(dian)管(guan)理(li)系(xi)統的“查(zha)詢(xun)商(shang)戶(hu)信(xin)息(xi)"接(jie)口,返(fan)回(hui)商戶(hu)的(de)基礎信(xin)息(xi),調(tiao)用(yong)“電(dian)費(fei)充值(zhi)"接口(kou)返(fan)回(hui)商戶(hu)的(de)卡(ka)號(hao)、充值金(jin)額、序(xu)列(lie)號(hao)等(deng)狀態信(xin)息(xi)。接(jie)口示例(li)如(ru)圖4所示。

通過(guo)Web管理(li)後臺(tai),商(shang)戶(hu)可自(zi)行(xing)查(zha)詢(xun)名下所有設施(shi)的(de)用(yong)水(shui)、電(dian)總(zong)量(liang)單(dan)項設施(shi)的(de)即(ji)時用(yong)量(liang)及(ji)狀態,也(ye)可以(yi)通(tong)過(guo)繳費(fei)清(qing)單(dan)查(zha)詢(xun)繳費(fei)記錄(lu),如(ru)圖5所示。

商戶(hu)費(fei)用(yong)繳納(na):商(shang)戶(hu)在(zai)學校(xiao)微信(xin)服(fu)務號上(shang),首(shou)先綁定為(wei)其開設的(de)校(xiao)園壹卡(ka)通(tong)賬號(hao),對(dui)校(xiao)園卡(ka)進(jin)行(xing)充(chong)值,然後使用(yong)校(xiao)園卡(ka)余額對(dui)水(shui)電費(fei)進行(xing)自(zi)助繳納(na),充(chong)值頁面同(tong)步顯(xian)示(shi)當(dang)前賬戶(hu)余額。充(chong)值(zhi)繳費(fei)頁面如(ru)圖6所示。

4系(xi)統測試和運行(xing)
為(wei)了檢(jian)測系(xi)統是否(fou)滿足功(gong)能需(xu)求、商(shang)戶(hu)管(guan)理(li)和使用(yong)過(guo)程中(zhong)各環(huan)節(jie)是(shi)否(fou)運(yun)行(xing)通(tong)暢,測試期(qi)建(jian)立了(le)測試商戶(hu)來(lai)模(mo)擬(ni)商(shang)戶(hu)使用(yong),並(bing)在試(shi)運行(xing)期(qi)間(jian)完善了壹些細(xi)節(jie)性問題如(ru):商(shang)戶(hu)線(xian)上(shang)充值(zhi)頁面增加(jia)“當(dang)前賬戶(hu)余額"展(zhan)示(shi),方便商戶(hu)查(zha)詢(xun)賬戶(hu)即(ji)時信息(xi);將(jiang)單(dan)個商戶(hu)下(xia)所有水電(dian)表的用(yong)量(liang)匯總實行(xing)統壹結(jie)算(suan),簡(jian)化(hua)結(jie)算(suan)流程;同(tong)時隨著商家(jia)的不斷入(ru)駐(zhu),在信(xin)號(hao)盲區(qu)增加(jia)基站(zhan)進行(xing)補(bu)盲覆蓋(gai)。
目(mu)前這(zhe)套(tao)IOT智(zhi)能水(shui)電表管理(li)系(xi)統已在(zai)校(xiao)內具體(ti)實施(shi)數(shu)月(yue)有余,運行(xing)良(liang)好(hao)。從學校(xiao)後勤(qin)、財務等管(guan)理(li)部(bu)門和使用(yong)商(shang)戶(hu)的(de)反(fan)饋來(lai)看(kan),此次(ci)將物(wu)聯網技術(shu)應用(yong)到(dao)校(xiao)園智(zhi)慧(hui)管(guan)理(li)的初步嘗(chang)試(shi)較為(wei)成功(gong)。
5AcrelEMS-EDU高(gao)校(xiao)綜合能效管理(li)平(ping)臺(tai)
5.1平(ping)臺(tai)概(gai)述(shu)
AcrelEMS-EDU校(xiao)園綜合能效管理(li)解決方案針(zhen)對校(xiao)園能源統計、後勤(qin)計(ji)費(fei)管理(li)、校(xiao)園運維(wei)管(guan)理(li)等提供(gong)高(gao)校(xiao)的信(xin)息(xi)化(hua)管(guan)理(li)平(ping)臺(tai)。從“源、網、荷(he)、儲(chu)、充"多(duo)個角(jiao)度解析(xi)高(gao)校(xiao)當下(xia)及未(wei)來(lai)的(de)用(yong)能(neng)問(wen)題(ti)及(ji)用(yong)能(neng)需(xu)求,在(zai)統壹的需(xu)求下(xia)“實現(xian)能(neng)源互補(bu)、信息(xi)互(hu)通"等管(guan)理(li)模式。助(zhu)力(li)學校(xiao)管理(li)智(zhi)能化(hua)、數(shu)字(zi)化(hua)、綜合化(hua),實現(xian)節(jie)能(neng)校(xiao)園、綠色校(xiao)園、低(di)碳(tan)校(xiao)園。
5.2平(ping)臺(tai)組成
AcrelEMS-EDU高(gao)校(xiao)綜合能效管理(li)平(ping)臺(tai)采(cai)用(yong)開放(fang)的(de)分(fen)層分布(bu)式網絡結(jie)構(gou),主(zhu)要由設備(bei)層、傳輸層、數據層、應用(yong)層組成。平(ping)臺(tai)融(rong)合電力(li)監(jian)控(kong)、電能統計、電(dian)氣安全(quan)、電(dian)能質(zhi)量(liang)分析(xi)及治理(li)、智(zhi)能照(zhao)明控(kong)制、預(yu)付費(fei)等功(gong)能,用(yong)戶(hu)通(tong)過(guo)瀏(liu)覽(lan)器、手機APP獲取(qu)數據,通過(guo)壹個平(ping)臺(tai)即(ji)可全(quan)局(ju)、整(zheng)體(ti)的(de)對(dui)企業用(yong)電(dian)進(jin)行(xing)進(jin)行(xing)集中(zhong)監(jian)控(kong)、統壹調度(du)、統壹運維(wei),同(tong)時滿足企業用(yong)電(dian)可靠、安(an)全(quan)、節(jie)約(yue)、高(gao)效、有(you)序(xu)的(de)要(yao)求。

圖1安科瑞高(gao)校(xiao)綜合能效管理(li)方案架構(gou)拓(tuo)撲(pu)
6.1校(xiao)園電力(li)監(jian)控(kong)與運維(wei)
集成設備(bei)所有數據(ju),綜合分析(xi)、協同(tong)控(kong)制、優(you)化(hua)運(yun)行(xing),集中(zhong)調控(kong),集中(zhong)監(jian)控(kong),數字(zi)化(hua)巡(xun)檢,移動運維(wei),班(ban)組重(zhong)新(xin)優(you)化(hua)整(zheng)合,減(jian)少(shao)人(ren)力(li)配(pei)置。

6.2後勤(qin)計(ji)費(fei)管理(li)
采(cai)用(yong)的(de)網絡抄表付費(fei)管理(li)技術(shu),實現(xian)電(dian)、水、氣等能源綜合計費(fei),實現(xian)遠程抄表、費(fei)率(lv)設置、賬單(dan)統計匯總等(deng),支(zhi)持(chi)微信(xin)、支(zhi)付寶(bao)、壹卡(ka)通(tong)等充值支(zhi)付方式,可設置補貼(tie)方案。通(tong)過(guo)能源付費(fei)管理(li)方式,培養(yang)用(yong)能(neng)群(qun)體(ti)和部(bu)門的(de)節(jie)能(neng)意(yi)識。
6.2.1宿(xiu)舍用(yong)電(dian)管(guan)理(li)
針對學生(sheng)宿(xiu)舍用(yong)電(dian)進(jin)行(xing)管(guan)理(li)控(kong)制:可批量下(xia)發(fa)基礎用(yong)電(dian)額(e)度(du)和定時通斷(duan)功能(neng);
可進(jin)行(xing)惡(e)性負載(zai)識別(bie),檢(jian)測違規電(dian)氣,並(bing)可獲取(qu)違規用(yong)電(dian)跳(tiao)閘(zha)記(ji)錄(lu);


6.2.2商(shang)鋪(pu)水電收(shou)費(fei)
針對(dui)校(xiao)園超(chao)市(shi)、商(shang)鋪(pu)、食堂及其他針(zhen)對(dui)個體(ti)的(de)水(shui)電用(yong)能(neng)進(jin)行(xing)預(yu)付費(fei)管理(li)


6.2.3充電樁管理(li)平(ping)臺(tai)
充(chong)電樁在“源、網、荷(he)、儲(chu)、充"信(xin)息(xi)能(neng)源結(jie)構(gou)中(zhong)是必。充電樁應用(yong)管(guan)理(li)同(tong)樣(yang)是校(xiao)園生(sheng)活(huo)服(fu)務中(zhong)必壹部(bu)分。


6.2.4智(zhi)能照(zhao)明管理(li)
通過(guo)對高(gao)校(xiao)路(lu)燈(deng)的(de)全(quan)局(ju)監(jian)測,提供(gong)對(dui)路(lu)燈(deng)靈(ling)活(huo)智(zhi)能的(de)管理(li),實現(xian)校(xiao)園內任(ren)壹線路(lu),任(ren)壹個路(lu)燈(deng)的(de)定時開關(guan)、強(qiang)制開關(guan)、亮(liang)度(du)調(tiao)節(jie),以(yi)及(ji)定時控(kong)制方案靈(ling)活(huo)設置,確保路(lu)燈(deng)照(zhao)明的智(zhi)能控(kong)制和高(gao)效節(jie)能(neng)。


6.3能源管理(li)系(xi)統
針對(dui)校(xiao)園水、電、氣等各類(lei)接入(ru)能(neng)源進行(xing)統計分(fen)析(xi),包含同(tong)比(bi)分(fen)析(xi)、環(huan)比(bi)分(fen)分析(xi)、損(sun)耗(hao)分析(xi)等。了解(jie)用(yong)能(neng)總(zong)量(liang)和能源流向(xiang)。
按校(xiao)園建(jian)築(zhu)的(de)分(fen)類(lei)進行(xing)采(cai)集和統計的(de)各類(lei)建(jian)築(zhu)耗(hao)電數(shu)據。如(ru)辦公(gong)類(lei)建(jian)築(zhu)耗(hao)電、教(jiao)學類(lei)建(jian)築(zhu)耗(hao)電、學生(sheng)宿(xiu)舍耗(hao)電等(deng),對數據(ju)分(fen)門別(bie)類(lei)的分(fen)析(xi),提供(gong)領導決(jue)策(ce),提(ti)高(gao)管理(li)效能。
構(gou)建(jian)符(fu)合校(xiao)園節(jie)能(neng)監(jian)管(guan)內容(rong)及(ji)要(yao)求的(de)數(shu)據庫,能自動完成能耗(hao)數據(ju)的采(cai)集工(gong)作,自(zi)動生(sheng)成各種形(xing)式(shi)的(de)報(bao)表、圖表以(yi)及(ji)系(xi)統性的能耗(hao)審計(ji)報告(gao),能(neng)夠(gou)監(jian)測能耗(hao)設備(bei)的(de)運(yun)行(xing)狀態,設置控(kong)制策略(lve),達(da)到節(jie)能(neng)目的(de)。

智(zhi)慧(hui)消防(fang)雲平(ping)臺(tai)基於物(wu)聯網、大數據(ju)、雲計算等現代信息(xi)技(ji)術(shu),將(jiang)分(fen)散(san)的火災(zai)自動報警(jing)設備(bei)、電(dian)氣火災(zai)監(jian)控(kong)設備(bei)、智(zhi)慧(hui)煙感探(tan)測器、智(zhi)慧(hui)消防(fang)用(yong)水(shui)等(deng)設備(bei)連(lian)接(jie)形(xing)成(cheng)網絡,並(bing)對這(zhe)些(xie)設備(bei)的(de)狀態進(jin)行(xing)智(zhi)能化(hua)感知、識別(bie)、定位,實時動態采(cai)集消防(fang)信息(xi),通(tong)過(guo)雲平(ping)臺(tai)進(jin)行(xing)數(shu)據分析(xi)、挖(wa)掘(jue)和趨勢分析(xi),幫助實現(xian)科學預(yu)警(jing)火災(zai)、網格化(hua)管(guan)理(li)、落實多(duo)元責(ze)任(ren)監(jian)管(guan)等目標。實現(xian)了(le)無人化(hua)值(zhi)守(shou)智(zhi)慧(hui)消防(fang),實現(xian)智(zhi)慧(hui)消防(fang)“自動化(hua)"、“智(zhi)能化(hua)"、“系(xi)統化(hua)"需(xu)求。從火災(zai)預(yu)防(fang),到火情報(bao)警(jing),再到控(kong)制聯動,在統壹的系(xi)統大平(ping)臺(tai)內運(yun)行(xing),用(yong)戶(hu)、安(an)保(bao)人員(yuan)、監(jian)管(guan)單(dan)位都能(neng)夠通過(guo)平(ping)臺(tai)直(zhi)觀地(di)看到每(mei)壹棟建(jian)築(zhu)物(wu)中(zhong)各類(lei)消防(fang)設備(bei)和傳感器的運(yun)行(xing)狀況(kuang),並(bing)能夠(gou)在出(chu)現細(xi)節(jie)隱(yin)患、發(fa)生(sheng)火情等(deng)緊(jin)急(ji)和非(fei)緊(jin)急(ji)情況(kuang)下,在(zai)幾秒(miao)時間(jian)內,相(xiang)關(guan)報(bao)警(jing)和事(shi)件(jian)信息(xi)通(tong)過(guo)手機短信、語(yu)音(yin)電(dian)話、郵件提(ti)醒(xing)和APP推送等(deng)手(shou)段(duan),就迅速能(neng)夠(gou)迅(xun)速通知(zhi)到(dao)達相關人員(yuan)。

7平(ping)臺(tai)部(bu)署(shu)硬(ying)件選型(xing)
7.1電力(li)監(jian)控(kong)與運維(wei)平(ping)臺(tai)
應用(yong)場(chang)合 | 產品 | 型(xing)號 | 功(gong)能(neng) |
變(bian)電所運維(wei)雲(yun)平(ping)臺(tai) |
| AcrelCloud-1000 | AcrelCloud-1000變(bian)電所運維(wei)雲(yun)平(ping)臺(tai)基於互(hu)聯網+、大數據(ju)、移動通訊等(deng)技(ji)術(shu)開發(fa)的(de)雲(yun)端(duan)管(guan)理(li)平(ping)臺(tai),滿足用(yong)戶(hu)或(huo)運(yun)維(wei)公(gong)司監(jian)測眾(zhong)多(duo)變電(dian)所回(hui)路(lu)運(yun)行(xing)狀態和參數、室(shi)內環(huan)境(jing)溫濕度(du)、電纜(lan)及母(mu)線(xian)運(yun)行(xing)溫度(du)、現場(chang)設備(bei)或(huo)環(huan)境(jing)視(shi)頻(pin)場(chang)景(jing)等需求,實現(xian)數(shu)據壹個,集中(zhong)存儲(chu)、統壹管理(li),方便使用(yong),支(zhi)持(chi)具有權限(xian)的(de)用(yong)戶(hu)通(tong)過(guo)電腦(nao)、手機、PAD等各類(lei)終(zhong)端鏈(lian)接訪(fang)問、接收(shou)報警(jing),並(bing)完成(cheng)有關(guan)設備(bei)日(ri)常(chang)和定期(qi)巡(xun)檢和派單(dan)等(deng)管(guan)理(li)工(gong)作。 |
智(zhi)能網關 |
| Anet系(xi)列 | 8個RS485串口2kV隔離,2個以(yi)太網接口,支(zhi)持(chi)ModbusRtu、IEC-60870-5-101/103/104、CJ/T188、DL/T645等通(tong)訊協(xie)議設備(bei)的(de)接(jie)入(ru),支(zhi)持(chi)ModbusRTU、ModbusTCP、IEC-60870-5-104等上(shang)傳協(xie)議、支(zhi)持(chi)多(duo)不同(tong)數(shu)據(ju)服務要求,支(zhi)持(chi)斷點續傳(chuan),裝(zhuang)置電源:220VAC/DC。 |
| ANet-2E4SM | 4路(lu)RS485串口,光(guang)耦(ou)隔離,2路(lu)以(yi)太網接口,支(zhi)持(chi)ModbusRtu、ModbusTC、DL/T645-1997、DL/T645-2007、CJT188-2004、OPCUA、ModbusTCP(主、從)、104(主、從)、建(jian)築(zhu)能(neng)耗(hao)、SNMP、MQTT;(主模(mo)塊)輸入(ru)電(dian)源:DC12V~36V。支(zhi)持(chi)4G擴(kuo)展模(mo)塊,485擴(kuo)展模(mo)塊,多(duo)可擴(kuo)展16路(lu)。 | |
10KV進(jin)/饋線 |
| AM6-L | 相(xiang)間(jian)電流速斷(duan)保(bao)護(hu),相間(jian)電流速斷(duan)保(bao)護(hu)(可帶(dai)低(di)壓(ya)閉(bi)鎖(suo)),相間(jian)過(guo)電流(liu)保護(hu)(可帶(dai)低(di)壓(ya)閉(bi)鎖(suo)),兩段(duan)式(shi)零(ling)序(xu)過(guo)流保(bao)護(hu),反時限(xian)相(xiang)間(jian)過(guo)流保(bao)護(hu)(可帶(dai)低(di)壓(ya)閉(bi)鎖(suo)),零(ling)序(xu)反(fan)時限(xian)過(guo)流保(bao)護(hu),過(guo)負荷(he)保(bao)護(hu),控(kong)制回(hui)路(lu)異(yi)常(chang)告(gao)警(jing)。 |
10/0.4KV變壓器 | AML-S | 分合閘位置、手車工(gong)作/試(shi)驗位置、接地刀(dao)閘(zha)位置、硬(ying)接點信(xin)號(hao)(保(bao)護(hu)跳(tiao)閘(zha)、裝(zhuang)置告(gao)警(jing)、控(kong)制回(hui)路(lu)斷(duan)線(xian)、裝(zhuang)置異常、未(wei)儲能、事(shi)故(gu)總等)、報(bao)文(wen)(過(guo)流、過(guo)負荷(he)、超(chao)溫報(bao)警(jing)、過(guo)溫報(bao)警(jing)、裝置告(gao)警(jing)、PT斷線、CT斷線、對(dui)時異常(chang)等)、遙控(kong)開關(guan)、故(gu)障波形(xing)分(fen)析(xi)(故(gu)障錄(lu)波、故(gu)障波形(xing)、故(gu)障記(ji)錄、跳(tiao)閘(zha)、故(gu)障電(dian)流電壓(ya))等。 | |
35kV/100kV/6kV 間(jian)隔智(zhi)能操(cao)控(kong)、 35kV/10kV/ 6kV傳感器 |
| ASD500 | 壹次回(hui)路(lu)動態模(mo)擬(ni)圖、彈簧(huang)儲能指(zhi)示(shi)、高(gao)壓帶(dai)電顯(xian)示(shi)及閉(bi)鎖(suo)、驗電、核(he)相(xiang)、自(zi)動溫濕度(du)控(kong)制及顯(xian)示(shi)(標配(pei)壹路(lu)強(qiang)制加(jia)熱(re))、遠方/就地旋(xuan)鈕(niu)、分(fen)合閘旋(xuan)鈕(niu)、儲(chu)能(neng)旋(xuan)鈕(niu)、人(ren)體(ti)感應、櫃(gui)內照(zhao)明控(kong)制、RS485接口(kou)、高(gao)壓櫃(gui)內電(dian)氣接點無線測溫。 |
35kV/10kV/ 6kV傳(chuan)感器 |
| 合金(jin)片固(gu)定,CT感應取(qu)電,啟(qi)動電流大於5A,測溫範(fan)圍-50-125℃,測量精(jing)度±1℃;無線傳輸距離空曠(kuang)150米; | |
35kV/10kV/6kV 間(jian)隔電參量測量 |
| APM810 | 三(san)相(I、U、kW、kvar、kWh、kvarh、Hz、cosΦ),零(ling)序(xu)電(dian)流(liu)In;四(si)象(xiang)限(xian)電(dian)能(neng);實時及需(xu)量;電(dian)流(liu)、電(dian)壓(ya)不平(ping)衡(heng)度;負載(zai)電流柱(zhu)狀圖顯示(shi);66種報警(jing)類(lei)型(xing)及外部(bu)事(shi)件(jian)(SOE)各16條事(shi)件(jian)記錄,支(zhi)持(chi)SD卡(ka)擴(kuo)展記(ji)錄;2-63次諧波;2DI+2DO RS485/Modbus;LCD顯(xian)示(shi); |
變壓(ya)器接頭測溫低(di)壓(ya)進(jin)出(chu)線櫃(gui)接(jie)頭測溫 |
| ARTM-Pn | 可至多(duo)配(pei)套(tao)60個ATE400測溫傳(chuan)感器,無線溫度(du)傳感器ATE400適用(yong)於手(shou)車(che)式動觸頭,電(dian)纜(lan)與母(mu)排(pai)搭(da)接處(chu),隔(ge)離刀(dao)閘(zha)搭(da)接處(chu)等(deng)電(dian)氣搭(da)接點的(de)溫度(du)測量,采(cai)用(yong)捆(kun)綁(bang)式(shi)安(an)裝。可使用(yong)ATC-400無線測溫接(jie)收(shou)器接收(shou)數據。該(gai)終(zhong)端可單(dan)獨(du)安(an)裝(zhuang)在(zai)高(gao)壓櫃(gui)、低(di)壓(ya)抽(chou)屜(ti)櫃(gui)內。 |
中(zhong)低(di)壓(ya)回(hui)路(lu) |
| WHD72-11 | WHD溫濕度(du)控(kong)制器產品主(zhu)要用(yong)於中(zhong)高(gao)壓開關(guan)櫃(gui)、端(duan)子(zi)箱、環(huan)網櫃、箱變(bian)等(deng)設備(bei)內部(bu)溫度(du)和濕度(du)調節(jie)控(kong)制。工(gong)作電(dian)源:AC/DC85~265V工(gong)作溫度(du):-40.0℃~99.9℃工(gong)作濕度(du):0RH~99RH |
| ADW300 | 三相(xiang)電參量U、I、P、Q、S、PF、F測量,有功電能(neng)計(ji)量(正、反向(xiang))、四(si)象(xiang)限(xian)無功電能、總(zong)諧波含量、分(fen)次(ci)諧波含量(2~31次(ci));A、B、C、N四(si)路(lu)測溫;1路(lu)剩(sheng)余電流(liu)測量;支(zhi)持(chi)RS485/LoRa/2G/4G/NB;LCD顯示(shi);有(you)功(gong)電(dian)能精(jing)度:0.5S級(ji)(改造(zao)項目) | |
| DTSD1352 | 三(san)相(xiang)電參量U、I、P、Q、S、PF、F測量,分相總有(you)功(gong)電能,總正反向(xiang)有功(gong)電能(neng)統計,總(zong)正(zheng)反向(xiang)無功電能統計;紅(hong)外通訊;電(dian)流(liu)規格:經互感器接入(ru)3×1(6)A,直(zhi)接接入(ru)3×10(80)A,有(you)功電能(neng)精(jing)度0.5S級(ji),無功電能精(jing)度2級(ji) |
7.2後勤(qin)計(ji)費(fei)管理(li)
7.2.1宿(xiu)舍/商(shang)業預(yu)付費(fei)平(ping)臺(tai)
7.2.2充電(dian)樁管理(li)平(ping)臺(tai)
應用(yong)場(chang)景(jing) | 型(xing)號 | 圖 片 | 保(bao)護(hu)功能(neng) |
充電樁管理(li)平(ping)臺(tai) | AcrelCloud-9000 | 采(cai)用(yong)泛(fan)在(zai)物(wu)聯、雲(yun)計(ji)算(suan)、大(da)數據、移動通訊、智(zhi)能傳(chuan)感等技(ji)術(shu)手(shou)段(duan)可為(wei)用(yong)戶(hu)提(ti)供(gong)能(neng)源數據(ju)采(cai)集、統計分(fen)析(xi)、能效分(fen)析(xi)、用(yong)能(neng)預(yu)警(jing)、設備(bei)管(guan)理(li)等服務,平(ping)臺(tai)可以(yi)廣(guang)泛應用(yong)於多(duo)種領域(yu)。 | |
新(xin)能源汽車充(chong)電(dian)樁 | AEV-AC007D-LCD |
| 輸入(ru)輸(shu)出(chu)電壓(ya):AC220V 1個充電(dian)接口(kou),充(chong)電(dian)線(xian)長5米;輸出(chu)功率(lv)7km;掃(sao)碼、刷卡(ka)支(zhi)付:標(biao)配(pei)無線通訊:4G、WIFI、藍(lan)牙(ya)三選壹(下單(dan)備(bei)註規格,無備註默(mo)認4G通訊)。 |
AEV-DC060S |
| 直(zhi)流(liu)60kw雙槍壹體(ti)充(chong)電(dian)機 | |
AEV-DC120S |
| 直流(liu)120kw雙槍壹體(ti)充(chong)電(dian)機 | |
智(zhi)能電(dian)動車充電樁 | ACX10系(xi)列 |
| 10路(lu)承載(zai)電(dian)流25A,單(dan)路(lu)輸(shu)出(chu)電流(liu)3A,單(dan)回(hui)路(lu)功(gong)率(lv)1000W,總功率(lv)5500W。充滿自停(ting)、斷電(dian)記(ji)憶、短路(lu)保(bao)護(hu)、過(guo)載保(bao)護(hu)、空載(zai)保護(hu)、故(gu)障回(hui)路(lu)識別(bie)、遠程升(sheng)級、功率(lv)識別(bie)、獨(du)立計(ji)量、告(gao)警(jing)上(shang)報。 ACX10A-TYHN:防(fang)護(hu)等級(ji)IP21,支(zhi)持(chi)投(tou)幣、刷卡(ka),掃(sao)碼、免費(fei)充電(dian) ACX10A-TYN:防(fang)護(hu)等級(ji)IP21,支(zhi)持(chi)投(tou)幣、刷卡(ka),免(mian)費(fei)充電(dian) ACX10A-YHW:防(fang)護(hu)等級(ji)IP65,支(zhi)持(chi)刷卡(ka),掃(sao)碼,免費(fei)充電(dian) ACX10A-YHN:防(fang)護(hu)等級(ji)IP21,支(zhi)持(chi)刷卡(ka),掃(sao)碼,免費(fei)充電(dian) ACX10A-YW:防(fang)護(hu)等級(ji)IP65,支(zhi)持(chi)刷卡(ka)、免(mian)費(fei)充電(dian) ACX10A-MW:防(fang)護(hu)等級(ji)IP65,僅支(zhi)持(chi)免費(fei)充電(dian) |
ACX2A系(xi)列 |
| 2路(lu)承載(zai)電(dian)流20A,單(dan)路(lu)輸(shu)出(chu)電流(liu)10A,單(dan)回(hui)路(lu)功(gong)率(lv)2200W,總功率(lv)4400W。充滿自停(ting)、斷電(dian)記(ji)憶、短路(lu)保(bao)護(hu)、過(guo)載保(bao)護(hu)、空載(zai)保護(hu)、故(gu)障回(hui)路(lu)識別(bie)、遠程升(sheng)級、功率(lv)識別(bie),報(bao)警(jing)上(shang)報。 ACX2A-YHN:防(fang)護(hu)等級(ji)IP21,支(zhi)持(chi)刷卡(ka)、掃(sao)碼充電(dian) ACX2A-HN:防(fang)護(hu)等級(ji)IP21,支(zhi)持(chi)掃(sao)碼充電(dian) ACX2A-YN:防(fang)護(hu)等級(ji)IP21,支(zhi)持(chi)刷卡(ka)充(chong)電 |
7.2.3智(zhi)能照(zhao)明管理(li)
應用(yong)場(chang)景(jing) | 產品 | 型(xing)號 | 功(gong)能(neng) | |
普通(tong)照(zhao)明 | 配(pei)電(dian)箱 |
| ASL220-S 系(xi)列 | 1、ALIBUS總(zong)線擴(kuo)展模(mo)塊,通信鏈路(lu)供(gong)電(dian)。 2、功(gong)耗(hao):≤5VA 3、4路(lu)16A磁(ci)保(bao)持(chi)繼(ji)電(dian)器輸出(chu),輸出(chu)可通(tong)過(guo)按鈕(niu)手(shou)動控(kong)制,輸出(chu)狀態液(ye)晶(jing)屏(ping)顯示。 4、2路(lu)開關(guan)量(liang)輸(shu)入(ru),可接(jie)入(ru)開關(guan)、報(bao)警(jing)、人體(ti)紅(hong)外感應器等信(xin)號(hao)。 5、外形(xing)尺寸:144mm(W)*90mm(H)*70mm(D)。 6、35mm標(biao)準(zhun)導軌式安(an)裝(zhuang) |
按鍵面(mian)板(ban) |
| ASL220-F1/2 | 1聯兩(liang)鍵 1、ALIBUS總(zong)線(xian)場(chang)景(jing)面板,通(tong)信(xin)鏈路(lu)供(gong)電(dian); 2、1聯2鍵輕(qing)觸按鍵,多(duo)彩(cai)背(bei)光(guang)指(zhi)示,金(jin)、黑、灰(hui)可選; 3、每個按鍵支(zhi)持(chi)長按、短按功能(neng),均可實現(xian)開關(guan)、調(tiao)光(guang)、場(chang)景(jing)控(kong)制; 4、外形(xing)尺寸:86mm(W)*86mm(H)*24mm(D); 5、86底(di)盒安裝(zhuang) | |
探(tan)測器 |
| ASL220-PM/T | PIR+照度(du)傳(chuan)感器 1、ALIBUS總線(xian)傳(chuan)感器,通信(xin)鏈(lian)路(lu)供(gong)電(dian),功(gong)耗(hao):20mA@24V; 2、特殊(shu)運算電(dian)路(lu),可通(tong)過(guo)紅(hong)外感應探(tan)測到人體(ti)動作; 4、安(an)裝方式:嵌入(ru)式(shi); 5、外形(xing)尺寸:ф80mm*33mm;產品外露尺寸:ф80mm*2.5mm | |
備(bei)用(yong)照(zhao)明 | 雙切(qie)箱 |
| ASL210-S 系(xi)列 | 1、ALIBUS總(zong)線擴(kuo)展模(mo)塊,通信鏈路(lu)供(gong)電(dian)。 2、功(gong)耗(hao):≤3VA 3、4路(lu)16A磁(ci)保(bao)持(chi)繼(ji)電(dian)器輸出(chu)。 4、1路(lu)開關(guan)量(liang)輸(shu)入(ru),可接(jie)入(ru)開關(guan)、報(bao)警(jing)、人體(ti)紅(hong)外感應器等信(xin)號(hao),1路(lu)485通(tong)訊。 5、外形(xing)尺寸:108mm(W)*90mm(H)*70mm(D)。 6、消防(fang)聯動啟(qi)動壹般照(zhao)明(備用(yong)照(zhao)明)。 7、35mm標準(zhun)導軌式安(an)裝(zhuang) |
應用(yong)場(chang)景(jing) | 產品 | 型(xing)號 | 功(gong)能(neng) | |
普通(tong)照(zhao)明 | 配(pei)電(dian)箱 |
| ASL220-S 系(xi)列 | 1、ALIBUS總(zong)線擴(kuo)展模(mo)塊,通信鏈路(lu)供(gong)電(dian)。 2、功(gong)耗(hao):≤5VA 3、4路(lu)16A磁(ci)保(bao)持(chi)繼(ji)電(dian)器輸出(chu),輸出(chu)可通(tong)過(guo)按鈕(niu)手(shou)動控(kong)制,輸出(chu)狀態液(ye)晶(jing)屏(ping)顯示。 4、2路(lu)開關(guan)量(liang)輸(shu)入(ru),可接(jie)入(ru)開關(guan)、報(bao)警(jing)、人體(ti)紅(hong)外感應器等信(xin)號(hao)。 5、外形(xing)尺寸:144mm(W)*90mm(H)*70mm(D)。 6、35mm標(biao)準(zhun)導軌式安(an)裝(zhuang) |
按鍵面(mian)板(ban) |
| ASL220-F1/2 | 1聯兩(liang)鍵 1、ALIBUS總(zong)線(xian)場(chang)景(jing)面板,通(tong)信(xin)鏈路(lu)供(gong)電(dian); 2、1聯2鍵輕(qing)觸按鍵,多(duo)彩(cai)背(bei)光(guang)指(zhi)示,金(jin)、黑、灰(hui)可選; 3、每個按鍵支(zhi)持(chi)長按、短按功能(neng),均可實現(xian)開關(guan)、調(tiao)光(guang)、場(chang)景(jing)控(kong)制; 4、外形(xing)尺寸:86mm(W)*86mm(H)*24mm(D); 5、86底(di)盒安裝(zhuang) | |
探(tan)測器 |
| ASL220-PM/T | PIR+照度(du)傳(chuan)感器 1、ALIBUS總線(xian)傳(chuan)感器,通信(xin)鏈(lian)路(lu)供(gong)電(dian),功(gong)耗(hao):20mA@24V; 2、特殊(shu)運算電(dian)路(lu),可通(tong)過(guo)紅(hong)外感應探(tan)測到人體(ti)動作; 4、安(an)裝方式:嵌入(ru)式(shi); 5、外形(xing)尺寸:ф80mm*33mm;產品外露尺寸:ф80mm*2.5mm | |
備(bei)用(yong)照(zhao)明 | 雙切(qie)箱 |
| ASL210-S 系(xi)列 | 1、ALIBUS總(zong)線擴(kuo)展模(mo)塊,通信鏈路(lu)供(gong)電(dian)。 2、功(gong)耗(hao):≤3VA 3、4路(lu)16A磁(ci)保(bao)持(chi)繼(ji)電(dian)器輸出(chu)。 4、1路(lu)開關(guan)量(liang)輸(shu)入(ru),可接(jie)入(ru)開關(guan)、報(bao)警(jing)、人體(ti)紅(hong)外感應器等信(xin)號(hao),1路(lu)485通(tong)訊。 5、外形(xing)尺寸:108mm(W)*90mm(H)*70mm(D)。 6、消防(fang)聯動啟(qi)動壹般照(zhao)明(備用(yong)照(zhao)明)。 7、35mm標準(zhun)導軌式安(an)裝(zhuang) |
IP網關 |
| ASL200-485-IP | IP協議轉換器(ALIBUS<-->TCP/IP) 1、1路(lu)ALIBUS通(tong)信(xin)總(zong)線(xian)接口。 2、1路(lu)RS485 3、1路(lu)以(yi)太網接口,以(yi)太網通訊 4、串口速率(lv)1200~115200bps可配(pei)置。串口支(zhi)持(chi)標準(zhun)MODBUS-RTU協議。 5、外形(xing)尺:96.6mm(W)*70mm(H)*18mm(D)。 6、35mm標準(zhun)導軌式安(an)裝(zhuang) 7、IP地址(zhi)設置連接、ALIBUS系(xi)統組網擴(kuo)容、ALIBUS通(tong)訊軟件(jian)連接 | |
IP輔助電(dian)源 |
| ASL200-P20 | 輔助電(dian)源 1、輸入(ru)電(dian)壓範(fan)圍:176-264VAC 2、輸(shu)出(chu)電壓(ya)及(ji)功(gong)率(lv):24VDC/20W 3、電壓調整(zheng)範(fan)圍:21.6~29V 4、工(gong)作溫度(du):-40~+70℃ 5、外形(xing)尺寸:96.6mm(W)*70mm(H)*18mm(D) 6、35mm標(biao)準(zhun)導軌式安(an)裝(zhuang) | |
7.3能源管理(li)系(xi)統
應用(yong)場(chang)景(jing) | 型(xing)號 | 圖 片 | 保(bao)護(hu)功能(neng) |
能耗(hao)管理(li)雲平(ping)臺(tai) | AcrelCloud-5000 |
| 采(cai)用(yong)泛(fan)在(zai)物(wu)聯、雲(yun)計(ji)算(suan)、大(da)數據、移動通訊、智(zhi)能傳(chuan)感等技(ji)術(shu)手(shou)段(duan)可為(wei)用(yong)戶(hu)提(ti)供(gong)能(neng)源數據(ju)采(cai)集、統計分(fen)析(xi)、能效分(fen)析(xi)、用(yong)能(neng)預(yu)警(jing)、設備(bei)管(guan)理(li)等服務,平(ping)臺(tai)可以(yi)廣(guang)泛應用(yong)於多(duo)種領域(yu)。 |
智(zhi)能網關 | Anet系(xi)列網管 |
| 采(cai)用(yong)嵌入(ru)式(shi)硬(ying)件計算機平(ping)臺(tai),具有多(duo)個下行(xing)通(tong)信接口(kou)及壹個或(huo)者(zhe)多(duo)個上(shang)行(xing)網絡接口(kou),作為(wei)信息(xi)采(cai)集系(xi)統中(zhong)采(cai)集終(zhong)端與(yu)平(ping)臺(tai)系(xi)統間(jian)的橋梁(liang),能夠根(gen)據(ju)不同(tong)的(de)采(cai)集規約(yue)進行(xing)水(shui)表、氣表、電表、微機保護(hu)等設備(bei)終(zhong)端的(de)數據(ju)采(cai)集匯總,並(bing)使用(yong)相(xiang)應的(de)規約(yue)轉發(fa)現(xian)場(chang)設備(bei)的(de)數(shu)據給平(ping)臺(tai)系(xi)統。 |
高(gao)壓重(zhong)要(yao)回(hui)路(lu)或(huo)低(di)壓(ya)進(jin)線櫃(gui) | APM810 |
| 具有全(quan)電(dian)量測量,電能統計,電(dian)能(neng)質(zhi)量(liang)分析(xi)及網絡通訊等(deng)功(gong)能,主要(yao)用(yong)於對(dui)電(dian)網供(gong)電(dian)質(zhi)量(liang)的綜合監(jian)控(kong)診斷及(ji)電(dian)能(neng)管(guan)理(li)。該(gai)系(xi)列儀表采(cai)用(yong)了(le)模(mo)塊(kuai)化(hua)設計(ji),當(dang)客(ke)戶(hu)需(xu)要(yao)增加(jia)開關(guan)量(liang)輸(shu)入(ru)輸(shu)出(chu),模擬(ni)量(liang)輸(shu)入(ru)輸(shu)出(chu),SD卡(ka)記(ji)錄,以(yi)太網通訊時,只需(xu)在背(bei)部(bu)插(cha)入(ru)對(dui)應模(mo)塊(kuai)即可。 |
APM520 |
| 三(san)相(xiang)全(quan)電(dian)量測量,2-63次諧波,不平(ping)衡(heng)度,大需量(liang),支(zhi)持(chi)付費(fei)率(lv),越限(xian)報(bao)警(jing),SOE,4-20mA輸出(chu)。 | |
低(di)壓(ya)聯絡(luo)櫃(gui)、出(chu)線櫃(gui) | AEM96 |
| 三(san)相(xiang)多(duo)功能(neng)電能(neng)表,均集成三相電(dian)力(li)參數測量及電能計(ji)量(liang)及考核(he)管(guan)理(li),提供(gong)上(shang)24時、上(shang)31日以(yi)及(ji)上(shang)12月(yue)的電(dian)能數據統計。具有63次分次(ci)諧波與(yu)總(zong)諧波含量檢(jian)測,帶(dai)有開關(guan)量(liang)輸(shu)入(ru)和繼(ji)電(dian)器輸出(chu)可實現(xian)“遙信"和“遙控(kong)"功能,並(bing)具備報警(jing)輸出(chu),可廣(guang)泛應用(yong)於多(duo)種控(kong)制系(xi)統,SCADA系(xi)統和能源管理(li)系(xi)統中(zhong)。 |
動力(li)櫃 | ACR120EL |
| 測量所有的常(chang)用(yong)電(dian)力(li)參數,如(ru)三(san)相電流、電壓(ya),有(you)功、無功功率(lv),電度,諧波等(deng),並(bing)具備完善的(de)通(tong)信聯網功能,非(fei)常適(shi)合於實時電力(li)監(jian)控(kong)系(xi)統。 |
DTSD1352 |
| DIN35mm導軌式安(an)裝(zhuang)結(jie)構(gou),體(ti)積小巧,能(neng)測量電能及其(qi)他(ta)電參量,可進(jin)行(xing)時鐘、費(fei)率(lv)時段(duan)等(deng)參數設置,精(jing)度高(gao)、可靠性好(hao)、性能指標(biao)符(fu)合國標GB/T17215-2002、GB/T17883-1999和電力(li)行(xing)業(ye)標準(zhun)DL/T614-2007對電能(neng)表的各項技術(shu)要(yao)求,並(bing)且(qie)具有電能脈(mai)沖(chong)輸出(chu)功能(neng);可用(yong)RS485通(tong)訊接(jie)口(kou)與上(shang)位機實現(xian)數(shu)據交換(huan)。 | |
AEW100 |
| 三(san)相全(quan)電(dian)量測量,剩(sheng)余電流(liu)、2-63次(ci)諧波,支(zhi)持(chi)付費(fei)率(lv),量值、電纜(lan)溫度(du),可選2G/4G通訊。 |
7.4智(zhi)慧(hui)消防(fang)系(xi)統
7.4.1電氣火災(zai)監(jian)控(kong)系(xi)統
應用(yong)場(chang)景(jing) | 產品 | 型(xing)號 | 功(gong)能(neng) | |
各變電(dian)所、各動力(li)箱 | 0.4KV出(chu)線 |
| ARCM200 系(xi)列 | 用(yong)於檢(jian)測TN-C-S、TN-S及局(ju)部(bu)TT系(xi)統中(zhong)的剩(sheng)余電流(liu)、溫度(du)等電(dian)氣參數,從而(er)預(yu)防(fang)電氣火災(zai)的發(fa)生(sheng)。 |
區域(yu)變(bian)電(dian)所 | 區域(yu)分(fen)機 |
| Acrel-6000/B3 | 接收(shou)電氣火災(zai)監(jian)控(kong)探(tan)測器信號(hao),實現(xian)對(dui)被保護(hu)電氣線路(lu)的(de)報(bao)警(jing)、監(jian)視(shi)、控(kong)制與管(guan)理(li),采(cai)用(yong)485通(tong)訊 |
主(zhu)變(bian)點所 監(jian)控(kong) | 控(kong)制主機 |
| Acrel-6000/B | 接(jie)收(shou)電氣火災(zai)監(jian)控(kong)探(tan)測器信號(hao)和各區域(yu)分(fen)機數據(ju),實現(xian)對(dui)被保護(hu)電氣線路(lu)的(de)報(bao)警(jing)、監(jian)視(shi)、控(kong)制與管(guan)理(li),可采(cai)用(yong)485通(tong)訊。 |
配(pei)套(tao)附件 | ||||
0.4kV電流 互感器 |
| AKH-0.66 | 測量型(xing)互感器,采(cai)集交流(liu)電(dian)流信(xin)號。 | |
7.4.2消防(fang)設備(bei)電(dian)源監(jian)控(kong)系(xi)統
應用(yong)場(chang)景(jing) | 產品 | 型(xing)號 | 功(gong)能(neng) | |
消防(fang)設備(bei)電(dian)源電壓(ya)監(jian)控(kong) |
| AFPM3-2AVM | 監(jian)測兩路(lu)三(san)相(xiang)交流(liu)電(dian)壓,二(er)總(zong)線通訊。 | |
區(qu)域(yu)變(bian)電(dian)所 | 區域(yu)分(fen)機 |
| AFPM100/B3 | 接收(shou)消防(fang)設備(bei)電(dian)源監(jian)控(kong)探(tan)測器信號(hao),實現(xian)對(dui)被保護(hu)電氣線路(lu)的(de)報(bao)警(jing)、監(jian)視(shi)、控(kong)制與管(guan)理(li),可采(cai)用(yong)二(er)總(zong)線通訊。 |
主(zhu)變(bian)點所監(jian)控(kong) | 控(kong)制主機 |
| AFPM100/B1 | 接(jie)收(shou)消防(fang)設備(bei)電(dian)源監(jian)控(kong)探(tan)測器信號(hao)和各區域(yu)分(fen)機數據(ju),實現(xian)對(dui)被保護(hu)電氣線路(lu)的(de)報(bao)警(jing)、監(jian)視(shi)、控(kong)制與管(guan)理(li),可采(cai)用(yong)二(er)總(zong)線通訊。 |
7.4.3防(fang)火門監(jian)控(kong)系(xi)統
應用(yong)場(chang)景(jing) | 產品 | 型(xing)號 | 功(gong)能(neng) | |
配(pei)電(dian)室(shi)、綜合樓 | 常開防(fang)火門 |
| AFRD-CK(YT)-65 AFRD-CK(YT)-85 AFRD-CK(YT)-120 | 監(jian)測常開防(fang)火門的(de)開閉(bi)狀態。 |
常(chang)閉(bi)防(fang)火門 |
| 單(dan)扇(shan):AFRD-CB1(YT) 雙扇(shan):AFRD-CB2(YT) | 監(jian)測常閉(bi)防(fang)火門的(de)開閉(bi)狀態。 | |
地(di)下箱體(ti)防(fang)爆車(che)間(jian) | 常開/常(chang)閉(bi)防(fang)火門 |
| AFRD-MC | 監(jian)測常開、常(chang)閉(bi)防(fang)火門的(de)開閉(bi)狀態。 |
監(jian)測模塊 |
| AFRD-CK/CB | 接收(shou)AFRD-MC的狀態信(xin)息(xi)同(tong)步傳(chuan)輸(shu)至防(fang)火門監(jian)控(kong)主機。 | |
區域(yu)變(bian)電(dian)所 | 區域(yu)分(fen)機 |
| AFRD100/B3 | 接收(shou)防(fang)火門監(jian)控(kong)模塊和防(fang)火門壹體(ti)式(shi)探(tan)測器的信(xin)號(hao),實現(xian)對(dui)防(fang)火門開閉(bi)狀態的(de)報警(jing)、監(jian)視(shi)、控(kong)制與管(guan)理(li),采(cai)用(yong)二(er)總(zong)線通訊。 |
主(zhu)變(bian)點所監(jian)控(kong) | 控(kong)制主機 |
| AFRD100/B | 接(jie)收(shou)防(fang)火門監(jian)控(kong)模塊和防(fang)火門壹體(ti)式(shi)探(tan)測器的信(xin)號(hao)以(yi)及(ji)各區域(yu)分(fen)機的實時數據(ju),實現(xian)對(dui)防(fang)火門開閉(bi)狀態的(de)報警(jing)、監(jian)視(shi)、控(kong)制與管(guan)理(li),采(cai)用(yong)二(er)總(zong)線通訊。 |
7.4.4消防(fang)應急(ji)照(zhao)明和疏(shu)散(san)指示系(xi)統
應用(yong)場(chang)合(綜合樓、汙水(shui)地(di)下(xia)箱體(ti)) | 產品 | 型(xing)號 | 功(gong)能(neng) | |
各變電(dian)所、地下箱體(ti)、綜合樓 | 集中(zhong)電源集中(zhong)控(kong)制型(xing)消防(fang)應急(ji)標(biao)誌燈具(高(gao)防(fang)護(hu)) |
| A-BLJC-1LROEII1W-A431H(單(dan)面(mian)安(an)全(quan)出(chu)口) | 防(fang)護(hu)等級(ji):IP67 設備(bei)尺寸:145*400*15 安(an)裝方式:壁(bi)掛(gua) |
| A-BLJC-1LROEII1W-A431H(單(dan)面(mian)疏(shu)散(san)出(chu)口) | 防(fang)護(hu)等級(ji):IP67 設備(bei)尺寸:145*400*15 安(an)裝方式:壁(bi)掛(gua) | ||
| A-BLJC-1LROEII1W-A431H(單(dan)面(mian)左向(xiang)) | 防(fang)護(hu)等級(ji):IP67 設備(bei)尺寸:145*400*15 安(an)裝方式:壁(bi)掛(gua) | ||
| A-BLJC-1LROEII1W-A431H(單(dan)面(mian)右(you)向(xiang)) | 防(fang)護(hu)等級(ji):IP67 設備(bei)尺寸:145*400*15 安(an)裝方式:壁(bi)掛(gua) | ||
| A-BLJC-1LROEII1W-A431H(單(dan)面(mian)雙向(xiang)) | 防(fang)護(hu)等級(ji):IP67 設備(bei)尺寸:145*400*15 安(an)裝方式:壁(bi)掛(gua) | ||
| A-BLJC-1LROEII1W-A431H(單(dan)面(mian)樓層) | 防(fang)護(hu)等級(ji):IP67 設備(bei)尺寸:145*400*15 安(an)裝方式:壁(bi)掛(gua) | ||
| A-BLJC-1LROEII1W-A431H(單(dan)面(mian)米標) | 防(fang)護(hu)等級(ji):IP67 設備(bei)尺寸:145*400*15 安(an)裝方式:壁(bi)掛(gua) | ||
集中(zhong)電源集中(zhong)控(kong)制型(xing)消防(fang)應急(ji)照(zhao)明燈具(高(gao)防(fang)護(hu)) |
| A-ZFJC-E*W-A604T8單(dan)管(guan)式(shi)應急(ji)照(zhao)明燈具 | 防(fang)護(hu)等級(ji):IP67 設備(bei)尺寸:Φ26*L400、Φ26*L600、Φ26*L1200 安(an)裝方式:吸頂、吊掛(gua) 設備(bei)功(gong)率(lv):3、6、9、12、15W | |
| A-ZFJC-E*W-A603HC高(gao)防(fang)護(hu)應急(ji)照(zhao)明燈具 | 防(fang)護(hu)等級(ji):IP67 設備(bei)尺寸:Φ175*H60 安(an)裝方式:吸頂、壁(bi)掛(gua) 設備(bei)功(gong)率(lv):3、6、9、12、15W | ||
| A-ZFJC-E*W-A603HE高(gao)防(fang)護(hu)應急(ji)照(zhao)明燈具 | 防(fang)護(hu)等級(ji):IP67 設備(bei)尺寸:198*98*55 安(an)裝方式:吸頂、壁(bi)掛(gua) 設備(bei)功(gong)率(lv):3、6、9、12、15W | ||
消防(fang)應急(ji)燈(deng)具電源 |
| A-D-0.3KVA-A200L A-D-0.5KVA-A200L A-D-0.75KVA-A200L A-D-0.1KVA-A200L | 防(fang)護(hu)等級(ji):IP65 設備(bei)尺寸:500*400*200、600*480*230 安(an)裝方式:壁(bi)掛(gua) 設備(bei)功(gong)率(lv):0.3、0.5、0.75、1KVA 回(hui)路(lu)數(shu)量(liang):8路(lu) | |
防(fang)爆工(gong)藝車間(jian) | 集中(zhong)電源集中(zhong)控(kong)制型(xing)消防(fang)應急(ji)防(fang)爆標(biao)誌(zhi)燈具 |
| A-BLJC-1LROEI1W-A431EX(防(fang)爆單(dan)面(mian)出(chu)口) | 防(fang)護(hu)等級(ji):IP65 防(fang)爆等(deng)級(ji):ExdeIICT6Gb/ExtDA21IP66T80℃ 設備(bei)尺寸:165*375*65 安(an)裝方式:壁(bi)掛(gua) |
| A-BLJC-1LROEI1W-A431EX(防(fang)爆單(dan)面(mian)左向(xiang)) | 防(fang)護(hu)等級(ji):IP65 防(fang)爆等(deng)級(ji):ExdeIICT6Gb/ExtDA21IP66T80℃ 設備(bei)尺寸:165*375*65 安(an)裝方式:壁(bi)掛(gua) | ||
| A-BLJC-1LROEI1W-A431EX(防(fang)爆單(dan)面(mian)右(you)向(xiang)) | 防(fang)護(hu)等級(ji):IP65 防(fang)爆等(deng)級(ji):ExdeIICT6Gb/ExtDA21IP66T80℃ 設備(bei)尺寸:165*375*65 安(an)裝方式:壁(bi)掛(gua) | ||
| A-BLJC-1LROEI1W-A431EX(防(fang)爆單(dan)面(mian)雙向(xiang)) | 防(fang)護(hu)等級(ji):IP65 防(fang)爆等(deng)級(ji):ExdeIICT6Gb/ExtDA21IP66T80℃ 設備(bei)尺寸:165*375*65 安(an)裝方式:壁(bi)掛(gua) | ||
| A-BLJC-1LROEI1W-A431EX(防(fang)爆單(dan)面(mian)樓層) | 防(fang)護(hu)等級(ji):IP65 防(fang)爆等(deng)級(ji):ExdeIICT6Gb/ExtDA21IP66T80℃ 設備(bei)尺寸:165*375*65 安(an)裝方式:壁(bi)掛(gua) | ||
| A-BLJC-2LROEI1W-A430EX(雙面(mian)安(an)全(quan)出(chu)口) | 防(fang)護(hu)等級(ji):IP65 防(fang)爆等(deng)級(ji):ExdeIICT6Gb/ExtDA21IP66T80℃ 設備(bei)尺寸:165*375*65 安(an)裝方式:吊管安裝 | ||
| A-BLJC-2LROEI1W-A430EX(多(duo)信息(xi)復(fu)合) | 防(fang)護(hu)等級(ji):IP65 防(fang)爆等(deng)級(ji):ExdeIICT6Gb/ExtDA21IP66T80℃ 設備(bei)尺寸:165*375*65 安(an)裝方式:吊管安裝 | ||
| A-BLJC-2LROEI1W-A430EX(雙面(mian)單(dan)向(xiang)) | 防(fang)護(hu)等級(ji):IP65 防(fang)爆等(deng)級(ji):ExdeIICT6Gb/ExtDA21IP66T80℃ 設備(bei)尺寸:165*375*65 安(an)裝方式:吊管安裝 | ||
| A-BLJC-2LROEI1W-A430EX(雙面(mian)雙向(xiang)) | 防(fang)護(hu)等級(ji):IP65 防(fang)爆等(deng)級(ji):ExdeIICT6Gb/ExtDA21IP66T80℃ 設備(bei)尺寸:165*375*65 安(an)裝方式:吊管安裝 | ||
集中(zhong)電源集中(zhong)控(kong)制型(xing)消防(fang)應急(ji)防(fang)爆照(zhao)明燈具 |
| A-ZFJC-E*W-A630EX | 防(fang)護(hu)等級(ji):IP65 防(fang)爆等(deng)級(ji):ExdeIICT6Gb/ExtDA21IP66T80℃ 設備(bei)尺寸:256*243*78 安(an)裝方式:壁(bi)掛(gua) 設備(bei)功(gong)率(lv):3、6、10W | |
| A-ZFJC-E*W-A632EX | 防(fang)護(hu)等級(ji):IP65 防(fang)爆等(deng)級(ji):ExdeIICT6Gb/ExtDA21IP66T80℃ 設備(bei)尺寸:Φ135mm*H168mm 安(an)裝方式:吊管安裝 設備(bei)功(gong)率(lv):3、6、9、12、15W | ||
消防(fang)應急(ji)燈(deng)具電源(防(fang)爆) |
| A-D-0.3KVA-A200EX A-D-0.5KVA-A200EX A-D-1KVA-A200EX | 防(fang)護(hu)等級(ji):IP43 設備(bei)尺寸:904*702*220、1354*702*220 安(an)裝方式:壁(bi)掛(gua) 設備(bei)功(gong)率(lv):0.3、0.5、1KVA 回(hui)路(lu)數(shu)量(liang):8路(lu) | |
區(qu)域(yu) 變(bian)電(dian)所 | 區域(yu)分(fen)機 |
| A-C-A100/B3 | 區(qu)域(yu)分(fen)機通過(guo)總線(xian)網絡實時監(jian)控(kong)各個終(zhong)端,在(zai)險情發(fa)生(sheng)時,自動將信息(xi)指(zhi)令發(fa)布(bu)到每個終(zhong)端,終(zhong)端收(shou)到指令之(zhi)後自(zi)動開始工(gong)作,如(ru)頻(pin)閃、變向(xiang)、開、滅燈等工(gong)作,實時指示(shi)佳、安全(quan)的(de)疏(shu)散(san)路(lu)線(xian)。 |
中(zhong)繼(ji)器 |
| CAN轉光(guang)纖(xian)中(zhong)繼(ji) | 通(tong)過(guo)CAN轉光(guang)纖(xian)中(zhong)繼(ji)實現(xian)把(ba)CAN總線傳(chuan)輸轉換(huan)至光(guang)纖(xian)傳輸延(yan)長(chang)通訊距離增加(jia)方案多(duo)樣(yang)性。 | |
主變電(dian)所 監(jian)控(kong) | 監(jian)控(kong)主機 |
| A-C-A100 | 監(jian)控(kong)主機通過(guo)總線(xian)網絡實時監(jian)控(kong)各個終(zhong)端,在(zai)險情發(fa)生(sheng)時,自動將信息(xi)指(zhi)令發(fa)布(bu)到每個終(zhong)端,終(zhong)端收(shou)到指令之(zhi)後自(zi)動開始工(gong)作,如(ru)頻(pin)閃、變向(xiang)、開、滅燈等工(gong)作,實時指示(shi)佳、安全(quan)的(de)疏(shu)散(san)路(lu)線(xian)。 |
8結(jie)束(shu)語
本文(wen)重(zhong)點介(jie)紹(shao)了(le)控(kong)制櫃與(yu)網關的軟硬(ying)件設計(ji)。經過(guo)調試(shi),該(gai)系(xi)統實現(xian)了(le)對1臺(tai)控(kong)制櫃的(de)操(cao)作,具有實時性、易操(cao)作性等優(you)點。而(er)對(dui)於群(qun)體(ti)的(de)控(kong)制以(yi)及(ji)前端界(jie)面(mian)的顯示(shi)還(hai)有(you)待進(jin)壹步研(yan)究(jiu)。
本文對(dui)遠程控(kong)制水表、煤(mei)氣表系(xi)統的設計(ji)也(ye)具有指導意(yi)義(yi)。對(dui)本(ben)系(xi)統稍(shao)加(jia)改(gai)進(jin),就可以(yi)用(yong)於水(shui)表、煤(mei)氣表等計(ji)量(liang)儀表的遠程操(cao)作,具有廣(guang)闊(kuo)的應用(yong)前途。
【參考文(wen)獻(xian)】
【1】田(tian)擁(yong)軍,趙(zhao)光(guang)強(qiang).基於ZigBee的(de)智(zhi)能用(yong)電(dian)管(guan)理(li)系(xi)統設計(ji)[J].中(zhong)國儀器儀表,2011(4):35-38.
【2】郭培.無線傳感器網絡以(yi)太網接人網關的研(yan)究(jiu)與實現(xian)[D].北(bei)京:北(bei)京交通(tong)大(da)學,2006:6-15.
【3】張少(shao)虎(hu).基於ZigBee的(de)自(zi)動抄表系(xi)統的設計(ji)[D].西(xi)安(an):西安科技(ji)大學,2009:25-36.
【4】孫偉,王建(jian)平(ping).無線傳感器網絡MAC層傳輸性能模型(xing)研(yan)究(jiu)[J].電子測量與儀器學報,2012,26(2):144-148.
【5】程(cheng)傑(jie),薛俏,邵(shao)芬紅(hong).基於無線網絡的學生(sheng)宿(xiu)舍用(yong)電(dian)管(guan)理(li)系(xi)統設計(ji)
【6】安(an)科瑞高(gao)校(xiao)綜合能效解決(jue)方案2022.5版(ban).
【7】安科瑞企業微電(dian)網設計(ji)與(yu)應用(yong)手(shou)冊(ce)2022.05版.