        1. 技術(shu)文(wen)章(zhang)您現在的位(wei)置:首(shou)頁 > 技術(shu)文(wen)章(zhang) > 中(zhong)低壓母線(xian)電弧光保護系統(tong)的(de)應用分(fen)析(xi)

          中低壓母線(xian)電弧光保護系統(tong)的(de)應用分(fen)析(xi)

          更新時(shi)間(jian):2023-11-28   點擊次(ci)數:831次

          摘(zhai)要:電弧光(guang)保護在變電(dian)站(zhan)運行(xing)過(guo)程(cheng)中(zhong)具(ju)有(you)十分(fen)重(zhong)要的意義,文(wen)章(zhang)對電力系(xi)統(tong)中(zhong)的(de)中(zhong)、低壓設(she)備的運行問(wen)題(ti)進(jin)行分(fen)析(xi),並且提出了電弧(hu)光保護方(fang)式(shi),迅(xun)速(su)切(qie)除(chu)變電(dian)站(zhan)運行(xing)過(guo)程(cheng)中(zhong)的故(gu)障點,保障變電(dian)站(zhan)的安(an)全穩定(ding)運行(xing)。

          關(guan)鍵(jian)詞(ci):電(dian)弧(hu)光(guang)保護;變電(dian)站(zhan);安全穩定(ding)運行(xing);燃(ran)弧(hu)耐(nai)受時(shi)間(jian)

          0引言(yan)

          在(zai)變電(dian)站(zhan)運行(xing)過(guo)程(cheng)中(zhong),安全性和穩(wen)定(ding)性是(shi)重(zhong)要因素,近(jin)年來(lai)在(zai)變電(dian)站(zhan)的建(jian)設(she)中(zhong),由(you)於戶(hu)內開關(guan)櫃(gui)占地(di)面積小(xiao),操(cao)作(zuo)集中(zhong),方(fang)便(bian)運(yun)行(xing)和維(wei)護等(deng)特(te)點,在變電(dian)站(zhan)中大(da)量(liang)配置中(zhong)低壓開(kai)關(guan)櫃(gui)運(yun)行(xing)過(guo)程(cheng)中(zhong)由(you)於各(ge)種原(yuan)因造(zao)成開(kai)關(guan)設(she)備被嚴重(zhong)燒(shao)毀(hui)的(de)事(shi)故(gu)越來(lai)越(yue)多,對變電(dian)站(zhan)事(shi)故(gu)的處(chu)理(li)不當(dang),會(hui)直(zhi)接影(ying)響(xiang)變電(dian)站(zhan)運行(xing)的(de)安全性與(yu)穩(wen)定(ding)性,導(dao)致電網(wang)事(shi)故(gu)不斷(duan)擴(kuo)大,不僅會(hui)帶(dai)來(lai)嚴重(zhong)的(de)經濟損失,還(hai)可(ke)能(neng)造(zao)成人(ren)員傷亡事(shi)故(gu)。在變電(dian)站(zhan)設(she)計(ji)過(guo)程(cheng)中(zhong),為(wei)了保證變壓(ya)器(qi)、母線(xian)、開關(guan)設(she)備的安全運行(xing),都(dou)遵(zun)照相(xiang)關(guan)規範(fan)配置保護裝置,但(dan)目(mu)前國(guo)內35kV及(ji)以(yi)下的(de)母線(xian)壹(yi)般不配置快(kuai)速(su)母線(xian)保護,而是由(you)變壓(ya)器(qi)的(de)後備過流保護來(lai)切(qie)除(chu)母線(xian)故(gu)障,由(you)後備保護動作切(qie)除(chu)故(gu)障的時(shi)間(jian)至少(shao)為(wei)0.5s,這樣(yang)就加大了對設(she)備的損傷程(cheng)度(du)。因此(ci),在(zai)變電(dian)站(zhan)中低壓開(kai)關(guan)櫃(gui)中(zhong)配置電(dian)弧(hu)光保護,壹(yi)旦(dan)出現(xian)故(gu)障,可(ke)以(yi)及(ji)時(shi)將故(gu)障切(qie)除(chu),防(fang)止(zhi)故(gu)障進壹(yi)步(bu)擴(kuo)大。

          1中(zhong)低壓開(kai)關(guan)櫃(gui)設(she)備運行過程(cheng)中(zhong)的問(wen)題(ti)和運(yun)行(xing)要求(qiu)

          1.1開(kai)關(guan)櫃(gui)設(she)備運行過程(cheng)中(zhong)的問(wen)題(ti)

          在(zai)變電(dian)站(zhan)設(she)計(ji)過(guo)程(cheng)中(zhong),110kV及(ji)以(yi)上的(de)母線(xian)會(hui)設(she)置母,電(dian)壓等(deng)級在35kV及(ji)以(yi)下的(de)母線(xian)系統(tong)中(zhong)壹(yi)般不配置快(kuai)速(su)母線(xian)保護,而是依(yi)賴上(shang)變壓(ya)器(qi)的(de)後備過流保護來(lai)切(qie)除(chu)母線(xian)短路故(gu)障,這樣導(dao)致了故(gu)障切(qie)除(chu)時(shi)間(jian)的延(yan)長,加大了(le)設(she)備的損傷程(cheng)度(du)。

          在(zai)設(she)備的使(shi)用(yong)過程(cheng)中(zhong)母線(xian)上的操作比較頻繁,設(she)備絕緣(yuan)老(lao)化、機(ji)械(xie)磨(mo)損(sun)是(shi)必(bi)然(ran)現象(xiang),運行(xing)條件(jian)發生改(gai)變以(yi)及(ji)人(ren)為(wei)操作(zuo)錯(cuo)誤(wu),會(hui)導(dao)致母線(xian)故(gu)障率升高(gao),對變電(dian)站(zhan)的運(yun)行(xing)存在安(an)全隱患(huan)。

          1.2開(kai)關(guan)櫃(gui)安(an)全運行(xing)要求(qiu)

          (1)開(kai)關(guan)櫃(gui)內(nei)部(bu)燃(ran)弧(hu)耐(nai)受時(shi)間(jian)。根據IEC298標(biao)準,開關(guan)櫃(gui)內(nei)部(bu)燃(ran)弧(hu)耐(nai)受時(shi)間(jian)為(wei)100ms,當(dang)前(qian)市(shi)面上銷售的開關(guan)櫃(gui)是(shi)按(an)照(zhao)該(gai)標(biao)準要求(qiu)設(she)計(ji)的(de),開關(guan)櫃(gui)使(shi)用(yong)過程(cheng)中(zhong)可(ke)以(yi)承(cheng)受(shou)的電弧燃(ran)燒(shao)時(shi)間(jian)為(wei)100ms。由(you)於電(dian)弧光故(gu)障壹(yi)般都(dou)發生在(zai)斷(duan)路器動(dong)作(zuo)前,故(gu)障短路電弧(hu)壹(yi)直(zhi)處(chu)於(yu)燃(ran)燒狀態(tai),保護動作時(shi)間(jian)與(yu)斷(duan)路器分(fen)閘(zha)時(shi)間(jian)之(zhi)和為(wei)電弧(hu)燃燒的持續時(shi)間(jian)。因此(ci),從(cong)開關(guan)櫃(gui)保護的角度(du)來(lai)講,保護動作應該(gai)要在100ms內迅(xun)速(su)做出響(xiang)應,對電弧(hu)短路故(gu)障進行切(qie)除(chu),防(fang)止(zhi)故(gu)障進壹(yi)步(bu)擴(kuo)大而(er)造(zao)成更大的危(wei)害。

          (2)開(kai)關(guan)櫃(gui)弧(hu)光(guang)故(gu)障防護。除了(le)加強(qiang)開(kai)關(guan)櫃(gui)的(de)結(jie)構外(wai),還(hai)應對母線(xian)配置快(kuai)速(su)保護,在開關(guan)櫃(gui)耐(nai)受燃(ran)弧時(shi)間(jian)以(yi)內切(qie)除(chu)故(gu)障,從根本上(shang)限制(zhi)故(gu)障電弧,對開關(guan)設(she)備的損壞和人(ren)員(yuan)安全的危(wei)害。

          2電(dian)弧光母線(xian)保護系統(tong)

          電(dian)弧光保護是壹(yi)種(zhong)快速(su)、可(ke)靠的(de)母線(xian)保護系統(tong),根(gen)據檢(jian)測(ce)弧光(guang)和過(guo)流(liu)雙判(pan)據原(yuan)理,能(neng)夠(gou)迅(xun)速(su)對變電(dian)站(zhan)中出(chu)現(xian)的故(gu)障進行響應,對於各(ge)種運(yun)行方(fang)式(shi)都(dou)適(shi)用(yong),為(wei)變電(dian)站(zhan)中低壓的(de)母線(xian)保護提供(gong)了解(jie)決方(fang)案(an)。電(dian)弧(hu)光保護系統(tong)主(zhu)要包括以(yi)下幾(ji)個(ge)方(fang)面的內容:

          2.1主(zhu)單(dan)元

          主(zhu)單(dan)元是電(dian)弧(hu)保護系統(tong)中(zhong)的(de)主(zhu)要部分(fen),主(zhu)要對短路電流(liu)以(yi)及(ji)來(lai)自電(dian)弧光(guang)傳感器(qi)的動作信(xin)息(xi)進行檢(jian)測(ce),並且對收(shou)集到(dao)的(de)故(gu)障信息(xi)進行處(chu)理(li)、判(pan)斷(duan),從而發出故(gu)障處(chu)理(li)信(xin)號,對故(gu)障進行切(qie)除(chu)。電(dian)弧(hu)光保護系統(tong)要在同(tong)時(shi)檢(jian)測(ce)到弧(hu)光和過(guo)流(liu)時(shi)才會(hui)發出相(xiang)應地切(qie)斷(duan)閘指令,如果進(jin)線斷(duan)路器沒(mei)有(you)及(ji)時(shi)動作(zuo)對故(gu)障進行切(qie)除(chu),則(ze)系(xi)統(tong)會(hui)啟動(dong)斷(duan)路器失(shi)靈(ling)保護邏輯,發出跳(tiao)閘(zha)指令跳(tiao)上(shang)級的斷(duan)路器進(jin)行(xing)故(gu)障切(qie)除(chu)。此(ci)外(wai),電(dian)弧保護系統(tong)的(de)主(zhu)單(dan)元還會(hui)根(gen)據輔(fu)助單(dan)元傳遞(di)的(de)弧光(guang)傳感器(qi)的動作信(xin)息(xi),對弧光(guang)故(gu)障點的位(wei)置進(jin)行(xing)確定(ding),發出溫度(du)報(bao)警(jing)信息(xi)。

          2.2輔(fu)助單(dan)元

          電(dian)弧保護系統(tong)的(de)輔(fu)助單(dan)元壹(yi)般都(dou)安裝在(zai)開關(guan)櫃(gui)中(zhong),每(mei)壹(yi)個(ge)輔(fu)助單(dan)元可(ke)以(yi)與(yu)10個(ge)弧光(guang)傳感器(qi)、1個(ge)溫度(du)傳(chuan)感器(qi)、1個(ge)便攜式(shi)弧光(guang)傳感器(qi)相(xiang)連。當(dang)系(xi)統(tong)發生弧(hu)光(guang)故(gu)障的時(shi)候(hou)輔(fu)助單(dan)元可(ke)以(yi)對弧光(guang)傳(chuan)感器(qi)中傳遞來(lai)的(de)動作(zuo)信息(xi)進行收(shou)集,並且將其(qi)傳遞(di)給(gei)主(zhu)單(dan)元,主單(dan)元再(zai)對故(gu)障進行分(fen)析(xi)和響(xiang)應。在主(zhu)單(dan)元中可(ke)以(yi)顯(xian)示(shi)輔(fu)助單(dan)元和弧(hu)光(guang)傳感器(qi)的地址編(bian)號(hao),有(you)助於(yu)及(ji)時(shi)對故(gu)障進行解除(chu)。

          2.3弧(hu)光傳感器(qi)

          弧(hu)光傳感器(qi)是對故(gu)障進行感應的主(zhu)要部件,安(an)裝(zhuang)在開(kai)關(guan)櫃(gui)的(de)各(ge)間(jian)隔室(shi)中(zhong),弧(hu)光傳感器(qi)是光感應元件,如果出(chu)現弧(hu)光(guang)故(gu)障時(shi),光強(qiang)度(du)大(da)幅度增加,傳感器(qi)檢(jian)測(ce)光強(qiang),將光信(xin)號(hao)轉(zhuan)換成(cheng)電流信號(hao),並且傳輸給(gei)輔(fu)助單(dan)元。

          2.4電(dian)流單(dan)元

          電(dian)流單(dan)元主要檢(jian)測(ce)系統(tong)中(zhong)電(dian)流(liu)的(de)變量(liang),並且可(ke)以(yi)將其(qi)送(song)到(dao)主(zhu)控單(dan)元上,對這些(xie)數據進(jin)行(xing)分(fen)析(xi)和處(chu)理(li),然(ran)後將處(chu)理(li)結(jie)果作(zuo)為(wei)判(pan)斷(duan)系統(tong)電(dian)流(liu)情況的(de)依(yi)據。

          2.5電(dian)弧光保護系統(tong)

          該(gai)系統(tong)采(cai)用(yong)弧光檢(jian)測(ce)和過(guo)電(dian)流檢(jian)測(ce)的方(fang)式(shi),實(shi)現(xian)對整個(ge)變電(dian)站(zhan)運行(xing)設(she)備的雙重檢(jian)測(ce)與(yu)判(pan)斷(duan),如果同(tong)時(shi)檢(jian)測(ce)到弧(hu)光與(yu)電(dian)流增(zeng)量信(xin)號,說(shuo)明設(she)備和系(xi)統(tong)出(chu)現(xian)了(le)故(gu)障,則(ze)需(xu)要快速啟動(dong)繼電(dian)器,發出跳(tiao)閘(zha)的指令(ling),當(dang)系(xi)統(tong)中(zhong)只(zhi)檢(jian)測(ce)到其(qi)中壹(yi)個(ge)信號(hao)的時(shi)候(hou),則(ze)只(zhi)需(xu)要發出報(bao)警(jing)信號(hao),通(tong)知(zhi)技術(shu)人(ren)員(yuan)系(xi)統(tong)出(chu)現(xian)故(gu)障即可(ke)。

          安(an)裝了電弧(hu)光(guang)保護裝置的(de)設(she)備和系(xi)統(tong)具(ju)有(you)斷(duan)路器失(shi)靈(ling)保護功能(neng),即當(dang)進(jin)線斷(duan)路器發生拒動的時(shi)候(hou),會(hui)發出越(yue)級(ji)跳(tiao)閘(zha)的信號(hao),從而對上短路信號(hao)進(jin)行切(qie)斷(duan),確保系統(tong)運(yun)行(xing)穩(wen)定(ding)。

          3電(dian)弧光保護在變電(dian)站(zhan)中的(de)應用

          本(ben)文(wen)以(yi)某(mou)變電(dian)站(zhan)為(wei)例,對電弧(hu)光(guang)保護在變電(dian)站(zhan)中的(de)應用進(jin)行分(fen)析(xi)與(yu)探(tan)討(tao)。

          某(mou)變電(dian)站(zhan)安裝(zhuang)應用了(le)ARB5型弧(hu)光保護系統(tong),幾(ji)年(nian)來(lai)系(xi)統(tong)的(de)運(yun)行(xing)十分(fen)穩(wen)定(ding)可(ke)靠,在(zai)保護母線(xian)方(fang)面發揮(hui)了(le)重要作用。本(ben)工(gong)程(cheng)的(de)接線方(fang)式(shi)為(wei)2條電(dian)源進(jin)線(xian),單(dan)母分(fen)段(duan),壹(yi)共有(you)14面開關(guan)櫃(gui)和2個(ge)母線(xian)橋。弧(hu)光(guang)保護配置的(de)方(fang)式(shi)主(zhu)要是:壹(yi)臺(tai)ARB5主(zhu)控單(dan)元,16個(ge)光探(tan)頭、300米光纖。將主控(kong)單(dan)元安裝(zhuang)在(zai)10kV進線(xian)櫃(gui)的(de)面板(ban)上,光(guang)探(tan)頭安裝在14面櫃(gui)以(yi)及(ji)兩個(ge)母線(xian)槽中。在對本工(gong)程(cheng)進(jin)行安(an)裝(zhuang)的時(shi)候(hou),是(shi)在(zai)處(chu)於(yu)運(yun)行過程(cheng)中(zhong)的變電(dian)站(zhan)上加(jia)裝(zhuang)弧光設(she)備,所(suo)以(yi)由(you)於停(ting)電的時(shi)間(jian)較短,為(wei)了保證能(neng)夠(gou)完(wan)成(cheng)安裝調(tiao)試工作,要提前做好準備。安裝的步(bu)驟(zhou)主(zhu)要為(wei)以(yi)下幾(ji)個(ge)方(fang)面:(1)根據變電(dian)站(zhan)加裝(zhuang)弧(hu)光系統(tong)的(de)實(shi)際情況,由(you)弧光(guang)系統(tong)設(she)備廠(chang)家的設(she)計(ji)人(ren)員對電氣(qi)安(an)裝圖紙進行設(she)計(ji),將圖紙提供(gong)給(gei)變電(dian)站(zhan)相(xiang)關(guan)技術(shu)人(ren)員(yuan)審(shen)核(he),結(jie)合變電(dian)站(zhan)的實(shi)際情況進(jin)行(xing)改進(jin),直到圖紙符合要求(qiu)。(2)對安裝(zhuang)所(suo)需(xu)要的輔(fu)材以(yi)及(ji)輔(fu)件進(jin)行(xing)準備,變電(dian)站(zhan)要根據設(she)計(ji)人(ren)員提(ti)供(gong)的圖(tu)紙,提前在(zai)開(kai)關(guan)櫃(gui)上(shang)開(kai)好裝置以(yi)及(ji)壓(ya)板(ban)安裝(zhuang)孔(kong),為(wei)安裝(zhuang)做好準備。(3)當(dang)變電(dian)站(zhan)確定(ding)停電(dian)時(shi)間(jian)之(zhi)後(hou),要提前通(tong)知(zhi)廠(chang)家,由(you)廠(chang)家安排(pai)技術(shu)人(ren)員(yuan)到(dao)現場進(jin)行(xing)配合安(an)裝。變電(dian)站(zhan)停電(dian)時(shi)要考慮(lv)綜合因素,確定(ding)具(ju)體(ti)時(shi)間(jian)。(4)在停(ting)電的(de)前壹(yi)天(tian)需(xu)要將主控(kong)制(zhi)裝置安(an)裝(zhuang)完畢(bi),停(ting)電(dian)之(zhi)後(hou),變電(dian)站(zhan)技術(shu)人(ren)員(yuan)要安排(pai)弧光(guang)設(she)備常見(jian)的技術(shu)人(ren)員(yuan),打(da)開開(kai)關(guan)櫃(gui)的(de)櫃(gui)門(men),在(zai)安(an)裝(zhuang)完畢(bi)之(zhi)後(hou)及(ji)時(shi)關(guan)閉櫃(gui)門(men)。(5)電(dian)源(yuan)的(de)進線(xian)、母線(xian)以(yi)及(ji)總(zong)控單(dan)元之(zhi)間(jian)的CT線(xian)可(ke)以(yi)由(you)變電(dian)站(zhan)技術(shu)人(ren)員(yuan)輔(fu)助敷(fu)設(she)完(wan)成(cheng),弧光(guang)保護出口(kou)所(suo)跳(tiao)開(kai)關(guan)也應該(gai)由(you)變電(dian)站(zhan)敷設(she)。(6)具(ju)體(ti)的(de)安裝和調(tiao)試過程(cheng)應該(gai)由(you)廠(chang)家技術(shu)人(ren)員(yuan)完(wan)成。(7)所(suo)有(you)的裝(zhuang)置調(tiao)試完畢(bi)之(zhi)後(hou),由(you)廠(chang)家的技術(shu)人(ren)員(yuan)對變電(dian)站(zhan)的技術(shu)人(ren)員(yuan)進(jin)行培(pei)訓(xun)。培訓(xun)之(zhi)後(hou)要進行測(ce)試,測(ce)試驗收(shou)合格(ge)之(zhi)後(hou)即完成(cheng)整個(ge)項目(mu)。

          在(zai)本項目(mu)中,電(dian)弧(hu)光(guang)保護系統(tong)要針對實(shi)際系(xi)統(tong)的(de)實(shi)際情況,在(zai)技術(shu)方(fang)面,電弧光(guang)保護裝置應該(gai)能(neng)夠(gou)提(ti)供(gong)“故(gu)障報警(jing)信號(hao)"、“故(gu)障動作信號(hao)"到計(ji)算(suan)機(ji)監(jian)控(kong)系(xi)統(tong),有(you)助於(yu)計算(suan)機(ji)監(jian)控(kong)系(xi)統(tong)及(ji)時(shi)發現變電(dian)站(zhan)設(she)備運行過程(cheng)中(zhong)的故(gu)障與(yu)問(wen)題,提(ti)高(gao)解(jie)決效率(lv),減(jian)少(shao)對電力傳(chuan)輸(shu)的影(ying)響(xiang)。同(tong)時(shi),電弧(hu)光(guang)保護的出口(kou)跳(tiao)閘(zha)繼電器(qi)應該(gai)要滿(man)足(zu)啟動(dong)功率(lv)不小(xiao)於(yu)5W、動(dong)作(zuo)電(dian)壓(ya)介於55-70之(zhi)間(jian)、動作(zuo)時(shi)間(jian)不小(xiao)於(yu)10ms的(de)要求(qiu)。

          對弧光(guang)保護系統(tong)進(jin)行(xing)安(an)裝(zhuang)的時(shi)候(hou),應該(gai)要遵(zun)循(xun)壹(yi)定(ding)的技術(shu)規範(fan):(1)KGN櫃(gui)的(de)安(an)裝(zhuang)。在(zai)安裝(zhuang)KGN櫃(gui)的(de)時(shi)候(hou)應該(gai)要按照保護母線(xian)隔室(shi)、母線(xian)側隔離刀閘(zha)室(shi)的(de)原(yuan)則(ze),在(zai)櫃(gui)子(zi)上(shang)側(ce)中(zhong)部進(jin)行安(an)裝,不僅可(ke)以(yi)確保有(you)足(zu)夠(gou)的(de)絕(jue)緣(yuan)距離(li),還(hai)能(neng)有(you)足(zu)夠(gou)的(de)角(jiao)度檢(jian)測(ce)到櫃(gui)內(nei)的(de)弧(hu)光(guang)是否(fou)滿(man)足(zu)要求(qiu)。對於本(ben)項(xiang)目(mu)中35kV的(de)開(kai)關(guan)櫃(gui)來(lai)講,應該(gai)在母線(xian)隔室(shi)、母線(xian)側隔離刀閘(zha)室(shi)中(zhong)各(ge)自安(an)裝壹(yi)個(ge)弧光(guang)傳感器(qi),如果是(shi)10kV,如果母線(xian)與(yu)母線(xian)側隔離刀閘(zha)同(tong)時(shi)在壹(yi)室(shi),則(ze)只(zhi)需(xu)要安裝壹(yi)個(ge)弧光(guang)傳感器(qi),如果母線(xian)和母線(xian)側隔離刀閘(zha)不在同(tong)壹(yi)室(shi),則(ze)需(xu)要分(fen)別(bie)安(an)裝(zhuang)弧光傳(chuan)感器(qi)。(2)KYN櫃(gui)安(an)裝(zhuang)。安(an)裝(zhuang)KYNN櫃(gui)的(de)時(shi)候(hou)只(zhi)能(neng)在(zai)母線(xian)隔室(shi)安(an)裝(zhuang),在上側中(zhong)部(bu)安裝(zhuang)不僅可(ke)以(yi)保證足(zu)夠(gou)的(de)絕(jue)緣(yuan)距離(li),還(hai)能(neng)保證及(ji)時(shi)檢(jian)測(ce)到櫃(gui)子(zi)內(nei)的(de)弧(hu)光。(3)為(wei)了避(bi)免電(dian)弧光保護的無選擇性跳(tiao)閘(zha)情況出(chu)現(xian),應該(gai)要進壹(yi)步(bu)簡(jian)化二(er)次回路,變電(dian)站(zhan)中的(de)35kV和10kV母線(xian)要采(cai)用(yong)分(fen)列(lie)運行(xing)的(de)方(fang)式(shi)。(4)新建(jian)的(de)變電(dian)站(zhan)在投(tou)產(chan)之(zhi)前(qian)應該(gai)要裝設(she)相(xiang)應的電(dian)弧光(guang)保護裝置,運(yun)行(xing)變電(dian)站(zhan)可(ke)以(yi)結(jie)合開(kai)關(guan)櫃(gui)的(de)大(da)修情況,假裝電弧光(guang)保護裝置。

          4安(an)科瑞(rui)ARB5-M弧光保護產(chan)品選型說(shuo)明

          ARB5-弧(hu)光主控單(dan)元

          技術(shu)參(can)數代碼(ma)

          代(dai)碼說(shuo)明

          弧(hu)光主控板(ban)數

          0

          0塊(kuai)主控板(ban),可(ke)接0塊采(cai)集板(ban)信號(hao)

          1

          1塊(kuai)主控板(ban),可(ke)接6塊采(cai)集板(ban)信號(hao)

          2

          2塊(kuai)主控板(ban),可(ke)接12塊采(cai)集板(ban)信號(hao)

          3

          3塊(kuai)主控板(ban),可(ke)接18塊采(cai)集板(ban)信號(hao)

          4

          4塊(kuai)主控板(ban),可(ke)接24塊采(cai)集板(ban)信號(hao)

          弧(hu)光采(cai)集板(ban)數

          0

          0塊(kuai)采(cai)集板(ban),可(ke)直接采(cai)集0個(ge)弧光(guang)探(tan)頭信號

          1

          1塊(kuai)采(cai)集板(ban),可(ke)直接采(cai)集5個(ge)弧光(guang)探(tan)頭信號

          2

          2塊(kuai)采(cai)集板(ban),可(ke)直接采(cai)集10個(ge)弧光(guang)探(tan)頭信號

          3

          3塊(kuai)采(cai)集板(ban),可(ke)直接采(cai)集15個(ge)弧光(guang)探(tan)頭信號

          4

          4塊(kuai)采(cai)集板(ban),可(ke)直接采(cai)集20個(ge)弧光(guang)探(tan)頭信號

          電(dian)流輸入

          1

          1A

          5

          電(dian)源

          1

          裝(zhuang)置電(dian)源(yuan)為(wei)DC110V,開入(ru)電源DC110V

          2

          裝(zhuang)置電(dian)源(yuan)為(wei)DC220V,開入(ru)電源DC220V

          3

          裝(zhuang)置電(dian)源(yuan)為(wei)AC110V,開入(ru)電源DC24V(裝置自帶(dai))

          4

          裝(zhuang)置電(dian)源(yuan)為(wei)AC220V,開入(ru)電源DC24V(裝置自帶(dai))

          電(dian)源

          0

          不需(xu)要

          1

          支(zhi)持MMS

          2

          支(zhi)持MMS,GOOSE

          (1)*表(biao)示(shi)可(ke)選附(fu)件(jian),需(xu)要另(ling)外(wai)增(zeng)加費用(yong)1500元。

          (2)主(zhu)控板(ban)和采(cai)集板(ban)數量之(zhi)和不能(neng)大(da)於(yu)4。

          (3)弧(hu)光探(tan)頭到采(cai)集板(ban)的長度不能(neng)超(chao)過20米(mi)。

          (4)如有(you)特(te)殊要求(qiu),請(qing)特(te)別註(zhu)明。

          5安(an)科瑞(rui)ARB5-M弧光保護產(chan)品功(gong)能(neng)和技術(shu)參(can)數

          型號(hao)

          主(zhu)要功能(neng)

          技術(shu)參(can)數

          ARB5-M弧(hu)光保護主控單(dan)元

          8組(zu)弧光保護

          可(ke)選配4塊采(cai)集板(ban),1塊采(cai)集板(ban)可(ke)采(cai)集5路探(tan)頭,共支(zhi)持20路弧光(guang)探(tan)頭直接采(cai)集。

          亦(yi)可(ke)選配4塊主控板(ban)(即可(ke)接入4臺(tai)ARB5-E擴(kuo)展單(dan)元)1塊主(zhu)控(kong)板(ban)可(ke)接收(shou)6塊(kuai)采(cai)集板(ban)的探(tan)頭,共支(zhi)持120路弧光(guang)探(tan)頭采(cai)集。

          4組(zu)失靈保護

          4組(zu)電流回路TA監測(ce)

          4組(zu)三相(xiang)電流(liu)采(cai)集

          11路可(ke)編(bian)程(cheng)跳(tiao)閘(zha)出口(kou)

          非電量保護

          裝(zhuang)置故(gu)障告警(jing)

          2路RS485

          2路以(yi)太(tai)網(wang)

          1路打印接口(kou)

          1路IRIG-B碼對時(shi)接口(kou)

          支(zhi)持IEC61850、modbusRTU、modbusTCP、IEC103

          支(zhi)持GOOSE輸(shu)入輸(shu)出(選配)

          ARB5-E弧(hu)光保護擴(kuo)展單(dan)元

          弧(hu)光信號采(cai)集

          可(ke)選配6塊采(cai)集板(ban),1塊采(cai)集板(ban)可(ke)采(cai)集5路探(tan)頭,共支(zhi)持30路弧光(guang)探(tan)頭直接采(cai)集。

          模擬狀(zhuang)態(tai)傳輸

          需(xu)要配合ARB5-M主(zhu)控單(dan)元使(shi)用(yong)

          ARB5-S弧(hu)光探(tan)頭

          弧(hu)光信號監(jian)測(ce)

          點式弧(hu)光(guang)傳感器(qi),可(ke)安裝(zhuang)於

          母線(xian)室(shi)、電(dian)纜室(shi)或(huo)斷(duan)路器室(shi)。

          現(xian)場調(tiao)試及(ji)工(gong)程(cheng)服(fu)務(wu)費

          視(shi)項目(mu)情況核(he)價

          6安(an)科瑞(rui)ARB5-M弧光保護產(chan)品現(xian)場安(an)裝(zhuang)

          弧(hu)光保護主控單(dan)元、探(tan)頭安裝圖如下。

          7結(jie)束語(yu)

          綜上(shang)所(suo)述(shu),采(cai)用(yong)電弧光(guang)保護系統(tong)對變電(dian)站(zhan)進行(xing)保護,其(qi)動作(zuo)時(shi)間(jian)為(wei)5-7ms,可(ke)以(yi)迅速(su)實(shi)現(xian)對故(gu)障的響應和處(chu)理(li),使(shi)變電(dian)設(she)備的損失減(jian)到(dao)小(xiao),大(da)大(da)提(ti)高(gao)了(le)變電(dian)站(zhan)運行(xing)的(de)安全性和運(yun)行(xing)效率(lv)。


          聯(lian)