安科瑞(rui)電(dian)氣股份(fen)有(you)限(xian)公(gong)司(si) 上(shang)海嘉定(ding)201801
摘(zhai)要:當前,電(dian)力(li)已成(cheng)為(wei)人(ren)們(men)生(sheng)活(huo)中(zhong)的壹(yi)部分,但(dan)是,在(zai)人(ren)們(men)的生(sheng)產和(he)生(sheng)活(huo)中(zhong)用(yong)電(dian)不(bu)當往往會(hui)導致建(jian)築物發生(sheng)電(dian)氣火(huo)災事(shi)故。面(mian)對嚴(yan)峻的電(dian)氣火(huo)災形(xing)勢,為(wei)保障建築用(yong)電(dian)安全,文(wen)章(zhang)對(dui)建(jian)築電(dian)氣火(huo)災事(shi)故的主要(yao)原因進行分析(xi),並(bing)提(ti)出相(xiang)應的預防(fang)措(cuo)施,為(wei)同類工(gong)程提(ti)供(gong)參(can)考。
關(guan)鍵(jian)詞(ci):建(jian)築電(dian)氣火(huo)災;事(shi)故原因;預防(fang)措(cuo)施
1建(jian)築電(dian)氣火(huo)災事(shi)故原因分析(xi)
(1)短路火(huo)災(zai)
在建(jian)築電(dian)氣系(xi)統(tong)運行(xing)期(qi)間(jian),受外(wai)部(bu)環境(jing)與動(dong)物啃食(shi)等因素影(ying)響(xiang),出現(xian)短路故障,電(dian)源(yuan)通(tong)向(xiang)用(yong)電(dian)設備(bei)的導線(xian)未經過(guo)負(fu)載(zai)而(er)直(zhi)接連接,進而產生(sheng)較(jiao)大(da)的短路電(dian)流,電(dian)流瞬間(jian)釋(shi)放大(da)量(liang)熱量(liang),引(yin)發絕緣(yuan)燒毀(hui)、導(dao)體(ti)變形(xing)損(sun)壞(huai)、金(jin)屬熔化、可(ke)燃(ran)物燃(ran)燒等(deng)壹(yi)系(xi)列問(wen)題(ti),最(zui)終(zhong)引(yin)發建築火災。而(er)電(dian)氣火(huo)災的主要(yao)機(ji)理(li)包括(kuo)接觸不(bu)良、炭(tan)化路徑(jing)短路、擊(ji)穿空(kong)氣(qi)放電(dian)、過負(fu)荷(he)、熱顆(ke)粒(li)噴(pen)濺(jian)、固(gu)體液體(ti)絕緣(yuan)擊(ji)穿、絕緣(yuan)過熱等(deng),如圖(tu)釘(ding)刺穿導體造(zao)成的接觸不(bu)良,短接電(dian)路受到(dao)磁(ci)場作(zuo)用(yong)與金(jin)屬加熱影(ying)響(xiang)產生(sheng)的預期(qi)電(dian)弧,出現(xian)短接故障時在(zai)短接部位噴(pen)濺(jian)的熱顆(ke)粒(li)。
以炭(tan)化路徑(jing)短路故障為例(li),由(you)於(yu)電(dian)流通過(guo)自身或(huo)是受外(wai)加(jia)作用(yong)而產生(sheng)的炭(tan)化路徑(jing)。這(zhe)壹(yi)故障的產生(sheng)機(ji)理(li)主要(yao)體(ti)現(xian)在(zai)三(san)方(fang)面(mian):第壹(yi),在物質上(shang)方(fang)施加(jia)熱源(yuan)加(jia)熱物質與出現(xian)建(jian)築火災時(shi),電(dian)路在(zai)高(gao)溫條件(jian)下容(rong)易(yi)出(chu)現(xian)炭(tan)化現(xian)象。第二,在線(xian)路持(chi)續出現(xian)表(biao)面(mian)電(dian)弧放電(dian)與電(dian)火花(hua)現(xian)象時,隨(sui)著(zhe)時間(jian)推(tui)移,導致兩(liang)個(ge)導(dao)體(ti)之間(jian)的空(kong)氣(qi)充分拉(la)弧,且後者將(jiang)具有(you)高(gao)溫和(he)相(xiang)當大的破(po)壞(huai)性(xing),最(zui)終(zhong)形(xing)成(cheng)炭(tan)化路徑(jing)。第三(san),如果兩(liang)相(xiang)導線(xian)間(jian)橫穿絕緣(yuan)形(xing)成(cheng)潮濕(shi)、受汙染的路徑(jing)時(shi),容(rong)易(yi)出(chu)現(xian)潮(chao)濕(shi)炭(tan)化路徑(jing)電(dian)弧。
此(ci)外,還(hai)可(ke)將(jiang)短路故障分為(wei)三(san)相(xiang)短路、兩(liang)相(xiang)短路與接地故障。不(bu)同故障的表現(xian)形(xing)式(shi)有(you)所(suo)不(bu)同,以接地故障為例(li),在連(lian)接導體(ti)與相(xiang)導體(ti)處(chu)於異(yi)常電(dian)接觸狀(zhuang)態(tai),故障相(xiang)電(dian)壓變(bian)為0,並(bing)構(gou)成(cheng)系(xi)統(tong)短路時(shi),可(ke)以判定為(wei)出現(xian)單(dan)相(xiang)接地故障。
(2)過載(zai)
受制(zhi)作(zuo)工藝、安裝質量(liang)等因素影(ying)響(xiang),存在過電(dian)流問題(ti),使得(de)線(xian)路處(chu)於過(guo)載(zai)運行(xing)狀(zhuang)態(tai),熱導(dao)體工(gong)作(zuo)溫度增加(jia),加(jia)快(kuai)線(xian)路老化速度,導致絕(jue)緣(yuan)強度下降。在線(xian)路老化至壹(yi)定程度,或是長(chang)時(shi)間(jian)處(chu)於過(guo)載(zai)運行(xing)狀(zhuang)態(tai)時(shi),將(jiang)造(zao)成絕(jue)緣(yuan)擊(ji)穿,出現(xian)短路故障。同時,在(zai)系(xi)統(tong)運行(xing)期(qi)間(jian)線(xian)路電(dian)壓異(yi)常波(bo)動(dong)時,在(zai)器件(jian)中(zhong)產生(sheng)不(bu)規(gui)則(ze)電(dian)壓,當實(shi)際(ji)電(dian)壓值(zhi)超過(guo)額定值(zhi)時(shi),引(yin)發介電(dian)擊(ji)穿與短路故障,而在(zai)線(xian)路設備(bei)老化程度過於(yu)嚴(yan)重(zhong)時,更容(rong)易(yi)在(zai)電(dian)壓波(bo)動(dong)時造(zao)成絕(jue)緣(yuan)擊(ji)穿,出現(xian)建(jian)築電(dian)氣火(huo)災事(shi)故。此(ci)外,可(ke)以將(jiang)過電(dian)壓故障分為(wei)大(da)氣(qi)過電(dian)壓、工(gong)頻過(guo)電(dian)壓、諧(xie)振過電(dian)壓和(he)操(cao)作(zuo)過(guo)電(dian)壓四(si)類故障。以工頻過(guo)電(dian)壓故障為例(li),在系(xi)統(tong)運行(xing)期(qi)間(jian),如果突(tu)然改(gai)變電(dian)網運行(xing)方(fang)式(shi),受到(dao)變(bian)電(dian)容(rong)影(ying)響(xiang),會(hui)產生(sheng)長(chang)線(xian)路電(dian)容(rong)效應,使得(de)線(xian)路電(dian)壓增加(jia),這(zhe)類故障具有(you)持(chi)續時間(jian)長和(he)過(guo)電(dian)壓倍(bei)數(shu)低的特征(zheng)。
(3)漏電(dian)
漏電(dian)是由(you)於(yu)線(xian)路絕(jue)緣(yuan)部位損壞(huai)或(huo)是自然老化等原因引(yin)發的電(dian)流泄漏故障,在泄漏部(bu)位產生(sheng)電(dian)弧與電(dian)火花(hua),通過釋(shi)放大(da)量(liang)熱量(liang)而引(yin)燃(ran)周(zhou)圍可(ke)燃(ran)物。針(zhen)對這(zhe)壹(yi)問題(ti),可(ke)以使用(yong)電(dian)筆(bi)等工(gong)具(ju)接觸帶(dai)電(dian)體,如(ru)果電(dian)筆(bi)的指示(shi)燈長時間(jian)處(chu)於點(dian)亮(liang)狀(zhuang)態(tai),則(ze)表(biao)明出(chu)現(xian)漏(lou)電(dian)故障,反之,則(ze)表(biao)明帶(dai)電(dian)體處(chu)於靜(jing)電(dian)狀(zhuang)態(tai)。
(4)不(bu)同性(xing)質短路火(huo)災(zai)
在出(chu)現(xian)短路故障時,根(gen)據(ju)短路間(jian)另(ling)壹(yi)端導(dao)體電(dian)位的短路接觸狀(zhuang)態(tai),可(ke)以將(jiang)短路引(yin)起(qi)的建築電(dian)氣火(huo)災分為(wei)金(jin)屬性(xing)短路和(he)電(dian)弧性(xing)短路兩(liang)種(zhong)性(xing)質。其中,金(jin)屬性(xing)短路故障表現(xian)為(wei),故障短路兩(liang)處(chu)導體(ti)接觸點(dian)在(zai)高(gao)溫條件(jian)下產生(sheng)熔(rong)化現(xian)象,使得(de)短路變(bian)為(wei)導電(dian)金(jin)屬,產生(sheng)較(jiao)大(da)的短路電(dian)流,這(zhe)壹(yi)故障的產生(sheng)原因包括(kuo)短路操(cao)作(zuo)時間(jian)保護過(guo)長(chang)、短路裝置(zhi)故障失效。例如(ru),在(zai)所(suo)配置熔(rong)斷器(qi)的材(cai)質質量(liang)不(bu)達(da)標(biao),或(huo)是熔(rong)斷(duan)器老化程度較(jiao)為(wei)嚴(yan)重(zhong)時,無法發揮(hui)出(chu)應有(you)作(zuo)用(yong),使得(de)短路電(dian)流燒傷(shang)線(xian)路,出(chu)現(xian)線(xian)芯燒紅(hong)外(wai)露與引(yin)燃(ran)可(ke)燃(ran)物等問(wen)題(ti)。為預(yu)防(fang)金(jin)屬性(xing)短路故障的出現(xian),可(ke)以在線(xian)路中(zhong)設置(zhi)鋁、鐵(tie)線(xian)材(cai)的熔斷器(qi)裝置(zhi),通過調整(zheng)熔(rong)絲連(lian)接情況來控(kong)制(zhi)短路操(cao)作(zuo)時間(jian)。
電(dian)弧性(xing)短路故障是在(zai)導(dao)體斷(duan)開(kai)與接入(ru)電(dian)路過(guo)程中(zhong),如(ru)果電(dian)源(yuan)電(dian)壓值(zhi)較(jiao)高(gao),將(jiang)會(hui)產生(sheng)高(gao)溫陣列與電(dian)弧,從絕(jue)緣(yuan)狀(zhuang)態(tai)切(qie)換(huan)至導電(dian)狀(zhuang)態(tai),這(zhe)壹(yi)現(xian)象被稱(cheng)作(zuo)為(wei)氣(qi)體(ti)放電(dian)現(xian)象,而所(suo)出(chu)現(xian)的電(dian)弧則(ze)是氣(qi)體(ti)放電(dian)的壹(yi)種(zhong)形(xing)式(shi)。與此(ci)同時,在(zai)電(dian)弧形(xing)成(cheng)期(qi)間(jian),將(jiang)會(hui)持(chi)續釋(shi)放大(da)量(liang)的熱能,將(jiang)局部溫度提(ti)高(gao)至3000℃左(zuo)右(you),進而引(yin)燃(ran)周(zhou)圍的可(ke)燃(ran)物,嚴重(zhong)時出現(xian)金(jin)屬熔化與蒸(zheng)發現(xian)象,有(you)較(jiao)高(gao)可(ke)能引(yin)發建築電(dian)氣火(huo)災。此(ci)外,在(zai)出(chu)現(xian)短路接地故障與雷(lei)過電(dian)壓問(wen)題(ti)時,也(ye)將(jiang)產生(sheng)電(dian)弧放電(dian)現(xian)象,出現(xian)電(dian)弧性(xing)短路故障。
(5)接觸不(bu)良
在建築電(dian)氣系(xi)統(tong)中(zhong),導(dao)電(dian)性(xing)電(dian)路是由(you)壹(yi)定數(shu)量(liang)的導電(dian)元件所(suo)組成(cheng),各導電(dian)元件之間(jian)通過(guo)機(ji)械連(lian)接方(fang)式(shi)保持(chi)導(dao)電(dian)接觸狀(zhuang)態(tai),這(zhe)壹(yi)現(xian)象被稱(cheng)作(zuo)為(wei)電(dian)接觸現(xian)象。然而(er),在部(bu)分建(jian)築電(dian)氣工(gong)程中(zhong),受到(dao)人(ren)為、工藝、環境(jing)等(deng)多(duo)方(fang)面(mian)因素影(ying)響(xiang),偶(ou)爾(er)出(chu)現(xian)電(dian)氣連(lian)接不(bu)當現(xian)象,導電(dian)元件間(jian)的實(shi)際(ji)接觸面(mian)積小(xiao)於設計(ji)面(mian)積,或(huo)是在(zai)接觸焊點(dian)表(biao)面(mian)附著(zhe)灰塵汙漬,設備(bei)機(ji)械連(lian)接松動(dong),造(zao)成導(dao)電(dian)元件接觸不(bu)良,最(zui)終(zhong)引(yin)發建築電(dian)氣火(huo)災事(shi)故。
(6)電(dian)氣線(xian)路設計(ji)負(fu)荷(he)與使用(yong)負(fu)荷(he)不(bu)匹(pi)配
在部(bu)分建(jian)築工程中(zhong),受設計(ji)因素影(ying)響(xiang),往往存在(zai)電(dian)氣線(xian)路設計(ji)負(fu)荷(he)與實(shi)際(ji)使用(yong)負(fu)荷(he)不(bu)匹(pi)配的問題(ti),在電(dian)氣設備(bei)與線(xian)路運行(xing)期(qi)間(jian),實(shi)際(ji)荷(he)載(zai)超過(guo)額定值(zhi)與可(ke)承受範(fan)圍(wei),長時間(jian)處(chu)於過(guo)載(zai)運行(xing)狀(zhuang)態(tai),不(bu)但(dan)加快(kuai)了(le)線(xian)路設備(bei)的老化速度,同時,還(hai)有(you)可(ke)能引(yin)發絕緣(yuan)擊(ji)穿、線(xian)路燒損(sun)、引(yin)燃(ran)周(zhou)圍可(ke)燃(ran)物等壹(yi)系(xi)列問(wen)題(ti)的出現(xian)。
(7)設備(bei)存(cun)在(zai)安全隱(yin)患
在(zai)部分建(jian)築電(dian)氣工(gong)程中(zhong),電(dian)氣設備(bei)與線(xian)路自身存(cun)在(zai)安全隱(yin)患,以某(mou)工(gong)程為(wei)例(li),壹(yi)方(fang)面(mian),沒有(you)正(zheng)確(que)認識到設備(bei)質量(liang)管理(li)工作(zuo)的重(zhong)要性(xing),在入(ru)場環節(jie),僅(jin)對設備(bei)外(wai)觀(guan)質量(liang)、規(gui)格(ge)型(xing)號(hao)與生(sheng)產許(xu)可(ke)證等(deng)資料文(wen)件(jian)進行審(shen)核(he)檢(jian)查,並未對設備(bei)內(nei)部(bu)結構(gou)情況進行檢(jian)查,也(ye)沒有(you)開(kai)展設備(bei)單(dan)體(ti)調(tiao)試(shi)試(shi)驗(yan),致使部分存(cun)在(zai)質量(liang)缺陷(xian)的設備(bei)被(bei)投(tou)入(ru)使用(yong)。另(ling)壹(yi)方(fang)面(mian),施工(gong)人(ren)員沒有(you)嚴(yan)格(ge)遵循相(xiang)關規(gui)範(fan)安裝電(dian)氣設備(bei)與敷(fu)設線(xian)路,存(cun)在(zai)設備(bei)安裝位置偏(pian)差、導(dao)電(dian)元件接觸不(bu)良、高(gao)溫設備(bei)與易燃(ran)物間(jian)隔(ge)過小(xiao)等(deng)問(wen)題(ti),在建(jian)築電(dian)氣系(xi)統(tong)運行(xing)期(qi)間(jian),存在(zai)安全隱(yin)患。
2建(jian)築電(dian)氣火(huo)災事(shi)故的有(you)效預防(fang)措(cuo)施
(1)加(jia)強設備(bei)管(guan)理(li)
在建(jian)築電(dian)氣安裝工(gong)程中(zhong),為(wei)預(yu)防(fang)電(dian)氣故障,應加強設備(bei)管(guan)理(li)力(li)度,禁止安裝存(cun)在質量(liang)缺陷(xian)的設備(bei)。首(shou)先(xian),在(zai)入(ru)場環節(jie),對(dui)電(dian)氣設備(bei)與線(xian)纜的結構(gou)質量(liang)進行檢(jian)查,開(kai)展單體(ti)設備(bei)試(shi)運行(xing)試(shi)驗(yan),從中(zhong)隨機(ji)抽取(qu)少量(liang)線(xian)纜等材(cai)料作(zuo)為(wei)試(shi)樣(yang),將(jiang)試(shi)樣(yang)送(song)至(zhi)實(shi)驗(yan)室檢(jian)測,根(gen)據(ju)試(shi)驗(yan)與檢測結果,退回(hui)存在(zai)質量(liang)缺陷(xian)的設備(bei)材(cai)料。其次,在電(dian)氣設備(bei)安裝完(wan)畢(bi)後,依次開(kai)展設備(bei)單(dan)體(ti)試(shi)運行(xing)與聯合調試(shi)試(shi)驗(yan),發現(xian)與處(chu)理(li)設備(bei)潛(qian)在(zai)故障,確保設備(bei)安裝質量(liang)達(da)標(biao)。最(zui)後,在(zai)工(gong)程驗(yan)收(shou)環節(jie),對(dui)施(shi)工(gong)成果質量(liang)進行全面(mian)性(xing)檢測,重(zhong)點(dian)檢(jian)查(zha)是否(fou)存在(zai)線(xian)路接線(xian)錯(cuo)誤(wu)、設備(bei)安裝位置偏(pian)移、導線(xian)接頭缺(que)乏(fa)保護、端(duan)子(zi)壓線(xian)過多(duo)等質量(liang)問題(ti),要求施工(gong)班組對(dui)其進行返工處(chu)理(li),確定(ding)電(dian)氣安裝質量(liang)達(da)到(dao)設計(ji)要求與工程建(jian)設標(biao)準後,再(zai)將(jiang)建築電(dian)氣工(gong)程交(jiao)付使用(yong)。
(2)日(ri)常維護保養(yang)與定期(qi)檢修(xiu)
首(shou)先(xian),做好(hao)線(xian)路設備(bei)的日(ri)常維護保養(yang)工(gong)作,清(qing)除(chu)設備(bei)線(xian)路表(biao)面(mian)附著(zhe)的灰塵汙漬,恢復設備(bei)線(xian)路運行(xing)狀(zhuang)態(tai),預(yu)防(fang)電(dian)氣故障與建築火災事(shi)故的出現(xian)。例(li)如(ru),清(qing)掃(sao)電(dian)路板(ban)表(biao)面(mian)的灰塵汙漬,如果電(dian)路板(ban)灰(hui)塵受潮(chao)不(bu)易(yi)清(qing)掃(sao),則(ze)使用(yong)*清(qing)洗(xi)電(dian)路板(ban),將(jiang)清(qing)洗(xi)後的電(dian)路板(ban)進行幹(gan)燥(zao)處(chu)理(li),祛(qu)除潮(chao)氣,避免電(dian)路板(ban)在(zai)受潮(chao)狀(zhuang)態(tai)下出(chu)現(xian)漏(lou)電(dian)故障。同時,對(dui)電(dian)氣設備(bei)與線(xian)路的運行(xing)狀(zhuang)態(tai)進行監測,記錄實(shi)時(shi)運行(xing)數(shu)據(ju),將(jiang)其與額定(ding)值(zhi)和(he)歷(li)史(shi)運行(xing)數(shu)據(ju)進行對(dui)比分析(xi),以此(ci)來判斷建(jian)築電(dian)氣系(xi)統(tong)和(he)單(dan)體(ti)設備(bei)的實(shi)時(shi)運行(xing)狀(zhuang)況(kuang),在(zai)發現(xian)異(yi)常情況時,及(ji)時(shi)組織(zhi)開(kai)展故障診斷(duan)與檢修(xiu)作(zuo)業(ye),在(zai)必(bi)要情況下斷(duan)開(kai)故障設備(bei)與非故障部位的連接,控制(zhi)故障影(ying)響(xiang)範圍和(he)受損(sun)程度,避免(mian)出(chu)現(xian)建(jian)築電(dian)氣火(huo)災。
其次,考慮到部分電(dian)氣故障具有(you)隱(yin)蔽性(xing)特征(zheng),很難通過(guo)目(mu)視(shi)檢(jian)查(zha)與數據(ju)分析(xi)方(fang)法來發現(xian)全部的電(dian)氣故障與安全隱(yin)患。因此(ci),需(xu)要定期(qi)開(kai)展全面(mian)性(xing)檢修(xiu)工(gong)作(zuo),在(zai)停(ting)機(ji)狀(zhuang)態(tai)下更換(huan)老舊(jiu)破(po)損與絕緣(yuan)擊(ji)穿的線(xian)路,將(jiang)電(dian)氣設備(bei)拆(chai)解為若幹(gan)部(bu)件,對(dui)各部件(jian)的磨損(sun)情況進行檢(jian)查處(chu)理(li),對松(song)動(dong)的零部件(jian)進行緊固處(chu)理(li)。待(dai)全部問題(ti)均得(de)到(dao)妥善(shan)處(chu)理(li)後,再(zai)恢(hui)復建築電(dian)氣系(xi)統(tong)的正常運行(xing)狀(zhuang)態(tai),藉(ji)此(ci)消除(chu)電(dian)氣安全隱(yin)患與設備(bei)線(xian)路潛(qian)伏故障。
(3)加強重(zhong)點(dian)部(bu)位防(fang)護
為(wei)預(yu)防(fang)短路、漏(lou)電(dian)、過載(zai)運行(xing)、接觸不(bu)良等常見電(dian)氣故障的出現(xian),需(xu)要對建築電(dian)氣系(xi)統(tong)中(zhong)的重(zhong)點(dian)部(bu)位采取(qu)防(fang)護措(cuo)施,在(zai)系(xi)統(tong)處(chu)於異(yi)常狀(zhuang)態(tai)時(shi),自動(dong)執(zhi)行相(xiang)應的保護動(dong)作,從(cong)而起(qi)到切(qie)斷(duan)故障部分與系(xi)統(tong)連(lian)接,或是恢(hui)復設備(bei)線(xian)路的正常運行(xing)。例(li)如(ru),在線(xian)路中(zhong)設置(zhi)過載(zai)保護裝置(zhi),裝置(zhi)將(jiang)持(chi)續對線(xian)路運行(xing)狀(zhuang)態(tai)進行監測,當電(dian)源(yuan)線(xian)路出(chu)現(xian)過(guo)載(zai)運行(xing)現(xian)象,致使保護器(qi)工(gong)作(zuo)溫度異(yi)常升高(gao)時,將(jiang)自動(dong)觸發過載(zai)保護裝置(zhi)的保護動(dong)作,對(dui)超出(chu)負(fu)荷(he)的行為進行保護,如(ru)啟(qi)動(dong)電(dian)源(yuan)設備(bei)自動(dong)斷開(kai)供(gong)電(dian)功能。同時,也(ye)可(ke)在系(xi)統(tong)中(zhong)設置(zhi)漏電(dian)保護器(qi),當系(xi)統(tong)的實(shi)際(ji)漏(lou)電(dian)值超過(guo)設定(ding)值後,漏(lou)電(dian)保護器(qi)將(jiang)自動(dong)切(qie)斷(duan)電(dian)源(yuan),並(bing)發出報(bao)警信號(hao)。
(4)故障仿真(zhen)分析(xi)與預防(fang)
考慮到多(duo)數電(dian)氣故障的發生(sheng)遵(zun)循特定(ding)規(gui)律(lv),可(ke)以提(ti)前開(kai)展故障仿真(zhen)分析(xi)試(shi)驗(yan),模擬(ni)不(bu)同工況(kuang)條(tiao)件下的電(dian)氣系(xi)統(tong)運行(xing)狀(zhuang)況(kuang)及(ji)過(guo)程,基(ji)於(yu)仿真(zhen)分析(xi)結果來(lai)準(zhun)確(que)判斷各類電(dian)氣故障乃至(zhi)建築電(dian)氣火(huo)災事(shi)故的出現(xian)規(gui)律(lv)、產生(sheng)原因、所造(zao)成具(ju)體影(ying)響(xiang),在其基(ji)礎上(shang)針(zhen)對性(xing)采取(qu)預防(fang)措(cuo)施,以及(ji)制(zhi)定(ding)事(shi)故應急處(chu)理(li)方(fang)案。例(li)如,在(zai)兩(liang)相(xiang)接地短路故障仿真(zhen)分析(xi)試(shi)驗(yan)中發現(xian),在(zai)主線(xian)路上(shang)的電(dian)壓波(bo)形(xing)與電(dian)流波(bo)形(xing)壹(yi)致時(shi),容(rong)易(yi)在(zai)變(bian)壓器高(gao)壓側(ce)與低壓(ya)側(ce)出(chu)現(xian)兩(liang)相(xiang)間(jian)短路故障,進而導(dao)致變(bian)壓(ya)器工(gong)作溫度異(yi)常升高(gao),在問(wen)題(ti)嚴重(zhong)時出現(xian)變(bian)壓(ya)器(qi)燒毀(hui)與全部用(yong)電(dian)設備(bei)停(ting)止(zhi)工(gong)作(zuo)的現(xian)象。最(zui)終(zhong),選(xuan)擇將(jiang)主線(xian)路的電(dian)壓與電(dian)流波(bo)形(xing)監測作為識別(bie)兩(liang)相(xiang)接地短路故障的主要(yao)手段。
(5)設備(bei)在(zai)線(xian)監測與故障自動(dong)識別(bie)
壹(yi)些電(dian)氣故障在早(zao)期(qi)階段呈現(xian)出(chu)明(ming)顯(xian)特征(zheng),如線(xian)路電(dian)流電(dian)壓值(zhi)異(yi)常波(bo)動(dong)、工作(zuo)溫度升高(gao)、發出異(yi)常聲響(xiang)、釋(shi)放電(dian)弧等,且(qie)電(dian)氣故障形(xing)成(cheng)與出現(xian)建(jian)築電(dian)氣火(huo)災之間(jian)存在(zai)時間(jian)差,如(ru)果在(zai)時(shi)間(jian)差內(nei)發現(xian)並(bing)解(jie)決電(dian)氣故障,可(ke)以有(you)效控制(zhi)故障造(zao)成的損失,避(bi)免出(chu)現(xian)建(jian)築火災。
憑(ping)借這(zhe)壹(yi)特性(xing),可(ke)選(xuan)擇引(yin)入(ru)在(zai)線(xian)自動(dong)監測技術(shu),在(zai)建(jian)築電(dian)氣系(xi)統(tong)中(zhong)設置(zhi)若幹(gan)種(zhong)類與數量(liang)的傳感(gan)器,持(chi)續對實(shi)時(shi)電(dian)流值、電(dian)壓值(zhi)、設備(bei)運行(xing)參(can)數等(deng)要(yao)素(su)進行監測識別(bie),並對(dui)周(zhou)邊環境(jing)進行感(gan)知(zhi)。隨後,裝置(zhi)將(jiang)采集現(xian)場監測信號(hao)上(shang)傳至系(xi)統(tong)處(chu)理(li),將(jiang)信號(hao)轉換後的監測數據與額定(ding)值(zhi)進行對(dui)比分析(xi),準(zhun)確(que)判斷建(jian)築電(dian)氣系(xi)統(tong)與單體(ti)設備(bei)的實(shi)時(shi)運行(xing)狀(zhuang)況(kuang),將(jiang)實(shi)時(shi)信息(xi)發布給(gei)管理(li)者。最(zui)後,當監測到異(yi)常狀(zhuang)況(kuang)時(shi),自動(dong)對故障類型(xing)與產生(sheng)原因進行診(zhen)斷,向(xiang)管(guan)理(li)人(ren)員發送(song)報(bao)警信號(hao),快(kuai)速組織(zhi)開(kai)展設備(bei)檢(jian)修(xiu)工(gong)作(zuo),將(jiang)診斷報(bao)告作為(wei)制(zhi)定(ding)檢修(xiu)計(ji)劃(hua)的主要(yao)依據(ju)。
(6)構(gou)建(jian)火(huo)災(zai)預警平臺(tai)
基(ji)於(yu)物聯網開(kai)發建築火災預(yu)警平臺(tai),在(zai)建築室內外(wai)區(qu)域(yu)中布置壹(yi)定數(shu)量(liang)的信息(xi)傳感(gan)裝置(zhi),持(chi)續對溫度、空(kong)氣(qi)濕(shi)度與空(kong)氣(qi)成分等(deng)要(yao)素(su)進行監測采集。如此(ci),在平臺(tai)運行(xing)期(qi)間(jian),將(jiang)持(chi)續調用(yong)並讀取(qu)溫度、煙(yan)霧濃度、濕(shi)度等數(shu)據(ju),將(jiang)監測數據與額定(ding)值(zhi)進行對(dui)比分析(xi),判斷是否(fou)超過(guo)閾值,如(ru)果任(ren)意(yi)壹(yi)項或多(duo)項數據超過(guo)安全閥(fa)值(zhi)時(shi),表(biao)明(ming)出現(xian)建(jian)築電(dian)氣火(huo)災事(shi)故,平臺(tai)將(jiang)自動(dong)發出警報(bao),通(tong)過(guo)網(wang)絡(luo)向(xiang)管(guan)理(li)人(ren)員、消防(fang)部門發送(song)相(xiang)關信息(xi),快(kuai)速組織(zhi)開(kai)展現(xian)場救(jiu)援(yuan)工作(zuo),快(kuai)速撲滅與有(you)效控制(zhi)火(huo)勢。
與此(ci)同時,在(zai)出(chu)現(xian)建(jian)築電(dian)氣火(huo)災事(shi)故時,火(huo)災預(yu)警平臺(tai)還(hai)將(jiang)通過信息(xi)傳感(gan)裝置(zhi),在三(san)維模型(xing)中(zhong)實(shi)時(shi)反映建(jian)築火勢蔓(man)延(yan)範(fan)圍(wei)與記錄相(xiang)關數(shu)據(ju),便於現(xian)場救(jiu)援(yuan)工作(zuo)的開(kai)展,以及(ji)對(dui)建(jian)築電(dian)氣火(huo)災事(shi)故出現(xian)原因的分析(xi),將(jiang)其為依據(ju)對建(jian)築電(dian)氣管(guan)理(li)體系(xi)和(he)具(ju)體(ti)的預防(fang)措(cuo)施方(fang)案進行改(gai)進,預防(fang)電(dian)氣故障與火災(zai)事(shi)故的反復出現(xian)。
(7)健(jian)全技術(shu)規(gui)範(fan)與管理(li)體系(xi)
近(jin)年(nian)來(lai),隨(sui)著(zhe)科技水(shui)平的不(bu)斷(duan)提(ti)高(gao),在建(jian)築工程中(zhong)使用(yong)了大(da)量(liang)的新型電(dian)氣設備(bei),建(jian)築電(dian)氣系(xi)統(tong)運行(xing)水(shui)平得(de)到(dao)明(ming)顯(xian)提(ti)升。然而(er),在相(xiang)關技術(shu)規(gui)範(fan)與電(dian)氣管(guan)理(li)體系(xi)中(zhong),卻(que)並未對新型(xing)設備(bei)的技術(shu)標(biao)準(zhun)、操(cao)作流程進行明(ming)確規(gui)定(ding),致使設備(bei)安裝質量(liang)與運行(xing)狀(zhuang)態(tai)受到(dao)人(ren)為主觀(guan)因素影(ying)響(xiang),存在安全隱(yin)患。因此(ci),需(xu)要定期(qi)對建(jian)築電(dian)氣工(gong)程的相(xiang)關技術(shu)規(gui)範(fan)和(he)設備(bei)運維管理(li)體系(xi)進行完(wan)善(shan)補充(chong),為設備(bei)安裝、調(tiao)試(shi)運行(xing)、維護保養(yang)、故障診斷(duan)與檢修(xiu)等(deng)具(ju)體(ti)活(huo)動(dong)的開(kai)展提(ti)供(gong)明(ming)確依據(ju)。
(8)人(ren)員管理(li)
人(ren)員是開(kai)展建築電(dian)氣設備(bei)安裝與電(dian)氣運行(xing)維護等(deng)活(huo)動(dong)的主體(ti),如(ru)果工(gong)作(zuo)人(ren)員的專業素(su)養(yang)不(bu)達(da)標(biao),或(huo)是缺(que)乏(fa)安全生(sheng)產意識,將(jiang)會(hui)形(xing)成(cheng)新的安全隱(yin)患,提(ti)高(gao)建築電(dian)氣火(huo)災事(shi)故與電(dian)氣故障的出現(xian)概(gai)率(lv)。因此(ci),加強人(ren)員管理(li)力(li)度,采取(qu)以下措(cuo)施,減少(shao)人(ren)為因素對(dui)建(jian)築用(yong)電(dian)安全造(zao)成的影(ying)響(xiang):第壹(yi),引(yin)入(ru)權(quan)責(ze)與問責(ze)機(ji)制(zhi)。明(ming)確劃分各部門人(ren)員的職(zhi)責範(fan)圍與工作(zuo)內(nei)容(rong),如(ru)電(dian)氣設備(bei)線(xian)路的日(ri)常維護保養(yang)內(nei)容(rong)。如(ru)此(ci),既可(ke)以確保預(yu)防(fang)措(cuo)施與管理(li)計劃(hua)得(de)到(dao)貫徹(che)執(zhi)行,同時,在(zai)受到(dao)人(ren)為因素影(ying)響(xiang)出現(xian)建(jian)築電(dian)氣火(huo)災事(shi)故時,可(ke)以對相(xiang)關責(ze)任(ren)人(ren)進行追責懲處(chu)。第二,事(shi)故案例(li)分析(xi)。定(ding)期(qi)舉(ju)辦(ban)案例(li)分析(xi)會(hui)議(yi),對(dui)同類工(gong)程的電(dian)氣火(huo)災事(shi)故案例(li)進行深(shen)入(ru)分析(xi),如(ru)分析(xi)事(shi)故的直(zhi)接、間(jian)接、根(gen)本(ben)、原因,探討各類建(jian)築電(dian)氣火(huo)災事(shi)故的正確處(chu)理(li)措(cuo)施,不(bu)斷(duan)總(zong)結建(jian)築電(dian)氣運維管理(li)與事(shi)故預防(fang)的工作經驗(yan)。第三(san),行為(wei)監督(du)。在建築電(dian)氣施(shi)工階段,對(dui)現(xian)場施(shi)工(gong)情況與操作(zuo)行(xing)為(wei)進行監督(du),及(ji)時(shi)糾正違章操(cao)作等(deng)不(bu)規(gui)範(fan)行(xing)為,及(ji)時(shi)發現(xian)並(bing)消(xiao)除(chu)安全隱(yin)患與質量(liang)問題(ti)。隨後,在(zai)建(jian)築電(dian)氣運維管理(li)階段,對(dui)設備(bei)線(xian)路日(ri)常維護、定(ding)期(qi)檢修(xiu)、故障診斷(duan)等工(gong)作(zuo)的開(kai)展情況進行監督(du)記錄,要(yao)求工作(zuo)人(ren)員嚴格(ge)遵循相(xiang)關操(cao)作(zuo)規(gui)範(fan)。
3安科瑞(rui)電(dian)氣火(huo)災監控(kong)系(xi)統(tong)
(1)概(gai)述(shu)
Acre1-6000電(dian)氣火(huo)災監控(kong)系(xi)統(tong),是根(gen)據(ju)國(guo)家現(xian)行(xing)規(gui)範(fan)標(biao)準由(you)安科瑞(rui)電(dian)氣股份(fen)有(you)限(xian)公(gong)司(si)研發的全數字化獨(du)立(li)運行(xing)的系(xi)統(tong),已通(tong)過(guo)國(guo)家消(xiao)防(fang)電(dian)子(zi)產品(pin)質量(liang)監督(du)檢驗(yan)中心(xin)的消防(fang)電(dian)子(zi)產品(pin)試(shi)驗(yan)認證,並(bing)且(qie)均通過(guo)嚴格(ge)的EMC電(dian)磁兼(jian)容(rong)試(shi)驗(yan),保證了(le)該系(xi)列產品(pin)在低壓(ya)配電(dian)系(xi)統(tong)中(zhong)的安全正常運行(xing),現(xian)均已批(pi)量(liang)生(sheng)產並在全國得(de)到(dao)廣(guang)泛(fan)地(di)應用(yong)。該系(xi)統(tong)通(tong)過(guo)對(dui)剩(sheng)余電(dian)流、過電(dian)流、過電(dian)壓、溫度和(he)故障電(dian)弧等信號(hao)的采集與監視(shi),實(shi)現(xian)對(dui)電(dian)氣火(huo)災的早期(qi)預防(fang)和(he)報(bao)警,當必(bi)要時(shi)還能聯動(dong)切(qie)除(chu)被檢測到剩(sheng)余電(dian)流、溫度和(he)故障電(dian)弧等超標(biao)的配電(dian)回(hui)路;並(bing)根(gen)據(ju)用(yong)戶的需(xu)求,還可(ke)以滿(man)足(zu)與AcreIEMS企(qi)業(ye)微(wei)電(dian)網管(guan)理(li)雲平臺(tai)或(huo)火災(zai)自動(dong)報(bao)警系(xi)統(tong)等(deng)進行數(shu)據交(jiao)換和(he)共(gong)享(xiang)。
(2) 應用(yong)場合(he)
適(shi)用(yong)於智能樓宇(yu)、高(gao)層公寓、賓館(guan)、飯(fan)店、商廈(sha)、工礦(kuang)企(qi)業(ye)、國家重(zhong)點(dian)消(xiao)防(fang)單位以及(ji)石(shi)油(you)化工、文(wen)教(jiao)衛(wei)生(sheng)、金(jin)融、電(dian)信等領(ling)域(yu)。
(3)系(xi)統(tong)結構(gou)
(4)系(xi)統(tong)功(gong)能
監控(kong)設備(bei)能接收(shou)多(duo)臺探測器的剩(sheng)余電(dian)流、溫度信息(xi),報(bao)警時(shi)發出聲、光(guang)報(bao)警信號(hao),同時設備(bei)上(shang)紅色“報(bao)警"指(zhi)示(shi)燈亮,顯(xian)示(shi)屏指(zhi)示(shi)報(bao)警部(bu)位及(ji)報(bao)警類(lei)型(xing),記(ji)錄報(bao)警時(shi)間(jian),聲光(guang)報(bao)警壹(yi)直(zhi)保持(chi),直(zhi)至(zhi)按設備(bei)的“復位"按鈕或觸摸(mo)屏(ping)的“復位"按鍵(jian)遠(yuan)程對(dui)探測器實(shi)現(xian)復位。對於聲音(yin)報(bao)警信號(hao)也(ye)可(ke)以使用(yong)觸摸(mo)屏(ping)“消聲"按(an)鍵(jian)手動(dong)消除(chu)。
當被監測回(hui)路報(bao)警時(shi),控(kong)制(zhi)輸出繼(ji)電(dian)器閉(bi)合,用(yong)於控(kong)制(zhi)被(bei)保護電(dian)路或(huo)其他設備(bei),當報(bao)警消(xiao)除(chu)後,控(kong)制(zhi)輸出繼(ji)電(dian)器釋(shi)放。
通(tong)訊故障報(bao)警:當監控(kong)設備(bei)與所接的任壹(yi)臺探測器之間(jian)發生(sheng)通(tong)訊故障或探測器本身發生(sheng)故障時,監控(kong)畫(hua)面(mian)中相(xiang)應的探測器顯(xian)示(shi)故障提(ti)示(shi),同時設備(bei)上(shang)的黃色“故障"指示(shi)燈亮,並發出故障報(bao)警聲音(yin)。電(dian)源(yuan)故障報(bao)警:當主電(dian)源(yuan)或(huo)備(bei)用(yong)電(dian)源(yuan)發生(sheng)故障時,監控(kong)設備(bei)也(ye)發出聲光(guang)報(bao)警信號(hao)並(bing)顯(xian)示(shi)故障信息(xi),可(ke)進入(ru)相(xiang)應的界面(mian)查看(kan)詳細信息(xi)並可(ke)解除(chu)報(bao)警聲響(xiang)。
當發生(sheng)剩(sheng)余電(dian)流、超溫報(bao)警或(huo)通(tong)訊(xun)、電(dian)源(yuan)故障時,將(jiang)報(bao)警部(bu)位、故障信息(xi)、報(bao)警時(shi)間(jian)等信息(xi)存儲在數(shu)據庫(ku)中(zhong),當報(bao)警解(jie)除(chu)、排(pai)除故障時,同樣(yang)予(yu)以記錄。歷(li)史(shi)數據(ju)提(ti)供(gong)多(duo)種(zhong)便捷、快(kuai)速的查詢方(fang)法。
(5) 配置方(fang)案
4結語(yu)
綜(zong)上(shang)所述(shu),為(wei)預(yu)防(fang)和(he)減少(shao)建築電(dian)氣火(huo)災事(shi)故的出現(xian),保證建(jian)築電(dian)氣系(xi)統(tong)安全穩定運行(xing)。因此(ci),掌握建(jian)築電(dian)氣火(huo)災事(shi)故的主要(yao)產生(sheng)原因,落實(shi)預(yu)防(fang)措(cuo)施,不(bu)斷(duan)對(dui)建(jian)築電(dian)氣管(guan)理(li)體系(xi)進行完(wan)善(shan)補充(chong),強化電(dian)氣設備(bei)日(ri)常維護與監督(du)管理(li)力(li)度,進壹(yi)步(bu)提(ti)高(gao)我國的建築電(dian)氣火(huo)災鑒定(ding)與預防(fang)水(shui)平。
參(can)考文(wen)獻
[1]劉(liu)海,劉平哈(ha).建(jian)築電(dian)氣火(huo)災的特點(dian)與滅火(huo)撲(pu)救(jiu)措(cuo)施的分析(xi)[J].電(dian)子(zi)世界,2018(17):161-161.
[2]黃劍(jian).施(shi)工現(xian)場電(dian)氣火(huo)災的原因分析(xi)及(ji)預(yu)防(fang)措(cuo)施[J].山(shan)西建(jian)築,2008,34(18):192-193.
[3]司(si)戈(ge).我國電(dian)氣火(huo)災的現(xian)狀(zhuang)、問(wen)題(ti)和(he)防(fang)控對策[J].消防(fang)技術(shu)與產品(pin)信息(xi),2008(06):3-8.
[4]司(si)戈(ge).我國建築電(dian)氣火(huo)災的現(xian)狀(zhuang)、問(wen)題(ti)和(he)防(fang)控對策[J].電(dian)氣工(gong)程應用(yong),2008(04):40-43.
[5]孟書(shu)瓏.電(dian)氣工(gong)程施(shi)工(gong)過(guo)程常見問題(ti)及(ji)預(yu)防(fang)措(cuo)施[J].矽(gui)谷(gu),2011(03):139-140.
[6]陳平樂(le).建(jian)築電(dian)氣火(huo)災事(shi)故原因分析(xi)及(ji)預(yu)防(fang)措(cuo)施[J].低(di)碳世(shi)界,2020,10(11):225-226.
[7]安科瑞(rui)企(qi)業(ye)微(wei)電(dian)網設計(ji)與應用(yong)手冊(ce)2022.5版
[8]解(jie)倩.建(jian)築電(dian)氣火(huo)災事(shi)故原因分析(xi)及(ji)預(yu)防(fang)措(cuo)施