1、 光(guang)伏(fu)並網(wang)櫃簡(jian)介(jie)
分(fen)布式並網(wang)光(guang)伏(fu)系統是(shi)利(li)用光(guang)伏(fu)組件(jian)將太(tai)陽(yang)能直接(jie)轉(zhuan)變(bian)為(wei)電(dian)能(neng)的發電(dian)方式,並且能壹定(ding)程度(du)保證發電(dian)的穩(wen)定(ding)性(xing)、可(ke)靠性(xing)及供(gong)給配(pei)電(dian)網(wang)電(dian)能(neng)質(zhi)量,是(shi)壹種新(xin)型的、環保型且(qie)具有長遠(yuan)發展前景的發電(dian)系(xi)統。該系統在用戶所(suo)在場(chang)地或(huo)附(fu)近建設(she)運(yun)行,以用戶側(ce)自(zi)發自(zi)用為(wei)主、多(duo)余電(dian)量上網(wang)且在(zai)配(pei)電(dian)網(wang)系統平衡調節為(wei)特征(zheng)的光(guang)伏(fu)發電(dian)設(she)施(shi)。它(ta)能夠(gou)就(jiu)近逐步解決(jue)用戶的用電(dian)問(wen)題,通(tong)過並網(wang)送去(qu)實現(xian)供(gong)電(dian)差(cha)額(e)的補(bu)償與(yu)外(wai)送。光(guang)伏(fu)電(dian)源(yuan)處(chu)於用戶側(ce),發電(dian)供(gong)給當(dang)地政(zheng)府負荷,可(ke)以有效減(jian)少對電(dian)網(wang)供(gong)電(dian)的依賴(lai),減(jian)少線(xian)路(lu)損耗(hao)。通過借(jie)助(zhu)建築(zhu)物(wu)表(biao)面(mian),將(jiang)光(guang)伏(fu)蓄(xu)電(dian)池(chi)作(zuo)為(wei)建築(zhu)材(cai)料,從而有效地增(zeng)加光(guang)伏(fu)電(dian)站(zhan)的占(zhan)地面(mian)積。分(fen)布(bu)式光(guang)伏(fu)發電(dian)系(xi)統規模(mo)較小(xiao),可(ke)以根(gen)據(ju)實際要求(qiu)進(jin)行建設(she),建設(she)區(qu)域(yu)選擇(ze)性(xing)較大,在(zai)未(wei)來能源(yuan)綜(zong)合利用發展中有很(hen)大(da)的發展空間(jian)。
並網(wang)櫃主(zhu)要(yao)由(you)刀(dao)閘(zha)、斷(duan)路(lu)器及有關的控(kong)制元(yuan)件(jian)組成,由(you)於(yu)其連(lian)接(jie)發電(dian)機(ji)系統和(he)電(dian)網(wang)系統,安(an)裝有完(wan)備的並網(wang)保護(hu)裝置,起到發電(dian)機(ji)並網(wang)作(zuo)用,而被(bei)稱(cheng)為(wei)“並網(wang)櫃"。 光(guang)伏(fu)並網(wang)櫃作(zuo)為(wei)光(guang)伏(fu)電(dian)站(zhan)的總(zong)出(chu)口存(cun)在於光(guang)伏(fu)系統中,是(shi)連(lian)接(jie)光(guang)伏(fu)電(dian)站(zhan)和(he)電(dian)網(wang)的配(pei)電(dian)裝置,可(ke)以保(bao)護(hu)、計(ji)量光(guang)伏(fu)發電(dian)的總(zong)量,方便故(gu)障(zhang)檢修管(guan)理(li),提高(gao)發電(dian)系(xi)統的安(an)全性(xing)和(he)經(jing)濟(ji)效益(yi)。具備(bei)檢失壓分閘(zha)、檢有壓合閘(zha)、過(guo)流保護、過電(dian)壓保護(hu)、孤(gu)島(dao)保護(hu)、防逆流保護、諧波治(zhi)理、無(wu)功補(bu)償等(deng)多(duo)項(xiang)保護(hu)功能(neng),同(tong)時具備(bei)顯示光(guang)伏(fu)發電(dian)系(xi)統運(yun)行參數和(he)狀態指示(shi),被(bei)廣(guang)泛(fan)運(yun)用於光(guang)伏(fu)發電(dian)系(xi)統,與光(guang)伏(fu)並網(wang)逆變(bian)器配套(tao)使用可(ke)組成壹套(tao)完(wan)整的光(guang)伏(fu)發電(dian)系(xi)統解決(jue)方案。
2、 光(guang)伏(fu)並網(wang)櫃綜(zong)合(he)監(jian)測解決(jue)方案
光(guang)伏(fu)並網(wang)櫃在(zai)運(yun)行中,會(hui)出(chu)現(xian)電(dian)網(wang)側(ce)電(dian)壓、頻率等(deng)方面(mian)的波動(dong)對本(ben)站(zhan)造成沖(chong)擊(ji)、負荷過(guo)高(gao)等(deng)現(xian)象(xiang),不(bu)僅(jin)會(hui)對電(dian)網(wang)設(she)備(bei)造成損壞還會(hui)威(wei)脅到維護人員的生(sheng)命(ming)安(an)全。諧(xie)波問(wen)題是(shi)光(guang)伏(fu)發電(dian)的最主要問(wen)題,光(guang)伏(fu)發電(dian)使用交、直流逆變(bian)器,由(you)於(yu)逆變(bian)器是(shi)通(tong)過半導體(ti)功率開關(guan)的開(kai)通(tong)和(he)關斷(duan)作(zuo)用,把直流電(dian)轉(zhuan)變(bian)成交流電(dian),在(zai)此(ci)環節會(hui)產(chan)生(sheng)諧(xie)波問(wen)題。另(ling)外(wai)由(you)於(yu)光(guang)伏(fu)項(xiang)目的不(bu)確定(ding)性(xing),造成輸出(chu)功率的隨機(ji)波動(dong),導(dao)致電(dian)網(wang)頻率偏(pian)差(cha)、電(dian)壓波動(dong)與(yu)閃(shan)變(bian)等(deng)。
針(zhen)對上述情(qing)況,本解決(jue)方案利用防孤(gu)島(dao)保護(hu)裝置采集並網(wang)電(dian)壓、頻率及電(dian)網(wang)進線(xian)電(dian)流等(deng)信(xin)號,當(dang)發生孤(gu)島(dao)現(xian)象(xiang)時,快(kuai)速切除(chu)並網(wang)點(dian),使本(ben)站(zhan)與電(dian)網(wang)側(ce)快(kuai)速脫離。同(tong)時配置(zhi)電(dian)能(neng)質(zhi)量在線(xian)監測裝置,對電(dian)壓諧波、電(dian)壓波動(dong)與(yu)閃(shan)變(bian)、頻率偏(pian)差(cha)、電(dian)壓不平衡度、電(dian)壓暫(zan)降/暫(zan)升(sheng)/短(duan)時中斷(duan)等(deng)進(jin)行實時監測。通(tong)過這兩種設(she)備(bei)在(zai)光(guang)伏(fu)並網(wang)櫃中(zhong)的使用,為(wei)電(dian)網(wang)的可(ke)靠運(yun)行提供(gong)保障(zhang)。本解決(jue)方案設(she)備(bei)配(pei)置方案如表壹。
表壹 配置(zhi)方案
3、 產(chan)品(pin)簡(jian)介(jie)
3.1 AM5SE-IS微(wei)機(ji)保護裝置
AM5SE-IS防孤(gu)島(dao)保護(hu)裝置主要適(shi)用於35kV、10kV及低(di)壓380V光(guang)伏(fu)發電(dian)、燃(ran)氣(qi)發電(dian)等(deng)新(xin)能源(yuan)並網(wang)供(gong)電(dian)系(xi)統。當(dang)發生孤(gu)島(dao)現(xian)象(xiang)時,可(ke)以快(kuai)速切除(chu)並網(wang)點(dian),使本(ben)站(zhan)與電(dian)網(wang)側(ce)快(kuai)速脫離,保(bao)證整個(ge)電(dian)站(zhan)和(he)相關(guan)維護人員的生(sheng)命(ming)安(an)全。
技(ji)術(shu)參(can)數
主(zhu)要(yao)功能(neng)
外(wai)形及開(kai)孔(kong)尺寸
外(wai)形尺寸 開孔尺寸
安(an)裝方法(fa)
裝置采用面(mian)板(ban)嵌入(ru)式安(an)裝,首先(xian)在(zai)屏(ping)體(ti)面(mian)板(ban)上按(an)開孔(kong)尺寸開孔,如圖1。再將裝置按(an)圖2所(suo)示放入(ru)開(kai)孔中,直到裝置面(mian)板(ban)靠住機(ji)櫃的面(mian)板(ban)。將支架放置(zhi)於機(ji)櫃面(mian)板(ban)的內部(上下各有壹個(ge)支架),如圖3,旋轉4個(ge)固(gu)定(ding)螺(luo)絲(si),使裝置牢固固(gu)定(ding)在(zai)機(ji)櫃面(mian)板(ban)上,最後(hou)蓋(gai)上4個(ge)翻(fan)蓋即可(ke)。(翻(fan)蓋上方有小(xiao)缺(que)口,拆(chai)卸時需(xu)用壹字螺(luo)絲刀(dao)插入(ru)小(xiao)缺(que)口將(jiang)翻(fan)蓋取下(xia)。)
3.2 APView500電(dian)能(neng)質(zhi)量在線(xian)監測裝置
APView500電(dian)能(neng)質(zhi)量在線(xian)監測裝置集諧波分(fen)析(xi)、波形采樣、電(dian)壓暫(zan)降/暫(zan)升(sheng)/中(zhong)斷(duan)、閃(shan)變(bian)監測、電(dian)壓不平衡度監測、事(shi)件(jian)記(ji)錄、測量控(kong)制等(deng)功能(neng)為(wei)壹體(ti),能(neng)夠滿足通(tong)過(guo)0.4-35kV電(dian)壓等(deng)級並網(wang)的分(fen)布(bu)式光(guang)伏(fu)發電(dian)系(xi)統要求(qiu),廣(guang)泛(fan)適(shi)用於工業(ye)廠房、商(shang)業(ye)屋(wu)頂(ding)、物(wu)流基地、機(ji)場交通(tong)、高(gao)速服務區(qu)等(deng)行業(ye)的分(fen)布(bu)式光(guang)伏(fu)並網(wang)點(dian)電(dian)能(neng)質(zhi)量監測。
技(ji)術(shu)參(can)數
監(jian)測精(jing)度
基(ji)本功能(neng)
註(zhu):√表(biao)示(shi)標配(pei)功能(neng),■表(biao)示(shi)可(ke)選(xuan)功能(neng)。
外(wai)形及開(kai)孔(kong)尺寸
本裝置為(wei)嵌入(ru)式安(an)裝方式,可(ke)以集(ji)中(zhong)安(an)裝於控(kong)制室(shi)的屏(ping)或(huo)櫃(gui)上,也可(ke)分(fen)散(san)安(an)裝於開關櫃(gui)上。
外(wai)形尺寸 開孔尺寸
4、 典(dian)型方案
4.1 0.4kV光(guang)伏(fu)發電(dian)項(xiang)目系(xi)統上圖
1、配(pei)電(dian)室(shi)上圖方案
壹次(ci)系統上圖
2、方案設(she)計(ji)
壹次(ci)方案設(she)計(ji)圖(tu)
4.2 10kV光(guang)伏(fu)發電(dian)項(xiang)目系(xi)統上圖
1、配(pei)電(dian)室(shi)上圖方案
10kV市(shi)電(dian)壹次(ci)系統圖
壹次(ci)系統上圖
2、方案設(she)計(ji)
壹次(ci)方案設(she)計(ji)圖(tu)