安科瑞(rui)電氣股(gu)份有(you)限(xian)公(gong)司(si) 上(shang)海(hai)嘉(jia)定(ding) 201801
摘(zhai)要(yao):隨(sui)著(zhe)社(she)會(hui)的進(jin)步、城市(shi)的發展,智能設(she)備已經與(yu)人(ren)們生(sheng)活息息相關(guan),本(ben)文就(jiu)智(zhi)能化(hua)在配(pei)電室(shi)的實施應(ying)用(yong)進(jin)行分(fen)析(xi)也為以(yi)後推廣(guang)實施奠定基(ji)礎(chu)。
關(guan)鍵(jian)詞(ci):結構(gou)分(fen)析(xi);智能優(you)化
0引言
智能化(hua)配電(dian)室系(xi)統(tong)由(you)智(zhi)能供(gong)配電(dian)系(xi)統(tong)、視(shi)頻(pin)、音頻監(jian)測控制(zhi)系(xi)統(tong)和停送電(dian)自(zi)動控制(zhi)系(xi)統(tong)構(gou)成(cheng)。
①智能化(hua)的配電(dian)櫃(gui)是在配(pei)電(dian)櫃上(shang)使(shi)用(yong)有(you)通(tong)信(xin)功能的綜合(he)保(bao)護(hu)裝(zhuang)置(zhi)和檢測儀表(biao);
②視(shi)頻(pin)、音頻監(jian)測控制(zhi)系(xi)統(tong):視(shi)頻(pin)、音頻監(jian)測控制(zhi)系(xi)統(tong)對(dui)智(zhi)能化(hua)配電(dian)室進(jin)行在線監(jian)測(ce),監控電氣設(she)備運行的數(shu)據;
③停(ting)送電(dian)自(zi)動控制(zhi)系(xi)統(tong):無(wu)人(ren)操作(zuo)的停送電(dian)自(zi)動控制(zhi)系(xi)統(tong)是以(yi)計(ji)算(suan)機或(huo)其他終端設備為基礎的、自(zi)動完成停送電(dian)控制(zhi)與(yu)監測(ce)的系(xi)統(tong)。無(wu)人(ren)看(kan)守智能化(hua)配電(dian)室,指的平時沒(mei)有(you)電(dian)氣操作(zuo)人(ren)員的智能化(hua)配電(dian)室。配(pei)電(dian)室的運行狀態通(tong)過各(ge)類傳感器(qi)收集信(xin)號並(bing)經過中間(jian)轉(zhuan)換(huan)設備處理匯(hui)集後,上(shang)傳至集控室上(shang)位機,供(gong)集控室值(zhi)班(ban)人(ren)員(yuan)隨(sui)時觀(guan)察(cha)或(huo)操作(zuo)壹些設備(專職(zhi)電(dian)工(gong)遠(yuan)程操作(zuo)電(dian)氣設(she)備)。
1智能化(hua)配電(dian)室結構(gou)
無(wu)人值守智能化(hua)高低(di)壓(ya)配電系(xi)統(tong)由(you)3個(ge)部(bu)分(fen)組成(cheng),分(fen)別為現場(chang)設備、通信(xin)網(wang)絡(luo)及(ji)相(xiang)關(guan)設備、集中監(jian)控平臺(tai)。現場(chang)設備包含直流屏(ping)、高(gao)壓開關(guan)櫃微(wei)電(dian)腦(nao)綜(zong)保裝(zhuang)置(zhi)、變壓器(qi)溫度(du)控制(zhi)裝(zhuang)置(zhi)、電容櫃(gui)及低(di)壓(ya)開關(guan)抽(chou)屜(ti)櫃(gui)綜(zong)合(he)保護(hu)裝(zhuang)置(zhi),主要(yao)向通(tong)信(xin)網(wang)絡(luo)提(ti)供(gong)監(jian)測(ce)參(can)數(shu)。通信網(wang)絡(luo)及(ji)設(she)備包含交(jiao)換(huan)機、網(wang)絡(luo)通(tong)信(xin)控制(zhi)器(qi)及通(tong)信(xin)光纜(lan)和其他附(fu)件。集中監(jian)控制(zhi)平(ping)臺(tai)是智能化(hua)配電(dian)室的控制(zhi)室(shi),主要(yao)包含視(shi)頻(pin)、音頻系(xi)統(tong)、工(gong)業(ye)控制(zhi)計(ji)算(suan)機、網(wang)絡(luo)通(tong)信(xin)服(fu)務(wu)器(qi)和其他輔(fu)助(zhu)設(she)備。
1.1現場(chang)設備
抽(chou)屜(ti)櫃(gui)式(shi)結構(gou)是現場(chang)高低(di)壓(ya)供配電櫃(gui)采用(yong)的主要(yao)結構(gou),每(mei)個抽(chou)屜(ti)櫃(gui)都是相對(dui)獨(du)立(li)的,各(ge)個(ge)電(dian)氣儀表(biao)和綜合保護(hu)裝(zhuang)置(zhi)互不(bu)影響,綜合(he)保(bao)護(hu)裝(zhuang)置(zhi)都留(liu)有(you)通(tong)信(xin)接(jie)口(kou),可(ke)以(yi)通(tong)過通信(xin)網(wang)絡(luo)與(yu)信(xin)號(hao)處理設備進(jin)行通信(xin),確(que)保(bao)實時監測高低(di)壓(ya)設備的數(shu)據並(bing)能保(bao)護(hu)、控制(zhi)高(gao)低(di)壓(ya)設備。
1.2通信(xin)網(wang)絡(luo)及(ji)相(xiang)關(guan)設備
每(mei)個配電室配備壹臺(tai)信息處理設備。配電(dian)室(shi)內(nei)所有(you)綜(zong)合(he)保(bao)護(hu)裝(zhuang)置(zhi)與信(xin)息處理設備進(jin)行通信(xin),對(dui)高(gao)低(di)壓(ya)設備實時運行數(shu)據進(jin)行采集、傳送和接(jie)收,對(dui)高(gao)低(di)壓(ya)設備進(jin)行遠(yuan)程控制(zhi)、對(dui)綜(zong)合(he)保(bao)護(hu)裝(zhuang)置(zhi)的參(can)數(shu)進(jin)行設置(zhi),實現配(pei)電室(shi)遠(yuan)程控制(zhi)。
1.3集中監(jian)控平臺(tai)
集中監(jian)視(shi)、控制(zhi)層(ceng)主要(yao)由視(shi)頻(pin)監(jian)控部(bu)分(fen)和人機操作(zuo)界面構(gou)成(cheng)。人機操作(zuo)界面采用(yong)專(zhuan)用(yong)組(zu)態監(jian)測(ce)控制(zhi)軟件,實時、準確地監測、控制(zhi)和記錄(lu)高低(di)壓(ya)電氣設(she)備的運行狀態,同(tong)時對(dui)負(fu)載(zai)進(jin)行控制(zhi)、對(dui)風(feng)險(xian)報(bao)警(jing)統計(ji),還可(ke)以(yi)對(dui)所(suo)有(you)的高低(di)壓(ya)系(xi)統(tong)電(dian)氣設(she)備進(jin)行遙(yao)控和遙(yao)信功能。視(shi)頻(pin)監(jian)視(shi)的功能是對(dui)配(pei)電(dian)室(shi)當前環(huan)境(jing)進(jin)行視(shi)頻(pin)、音頻監(jian)控,在保(bao)證(zheng)高(gao)低(di)壓(ya)設備安全(quan)運行的同時,對(dui)高(gao)低(di)壓(ya)電氣設(she)備進(jin)行“遙(yao)視(shi)"。
2實現智(zhi)能化(hua)配電(dian)室的目(mu)標(biao)
優(you)化各(ge)類生(sheng)產工(gong)藝(yi)、降(jiang)低(di)運(yun)行成本(ben)是每(mei)個地面生(sheng)產系(xi)統(tong)設(she)備發展的必(bi)經之(zhi)路(lu)。智能化(hua)配電(dian)室的使(shi)用(yong),是地面生(sheng)產系(xi)統(tong)實現減員增(zeng)效(xiao)、管理創(chuang)新(xin)的重(zhong)要(yao)措施(shi)。而作(zuo)為自(zi)動化、智能化(hua)地面生(sheng)產系(xi)統(tong)的壹部(bu)分(fen),智能化(hua)的配電(dian)室(shi)具有(you)以(yi)下3個作用(yong):
①實現高(gao)低(di)壓(ya)電氣設(she)備的遠(yuan)程停(ting)送電(dian),保證安全(quan)生(sheng)產;
②配(pei)電(dian)室(shi)電(dian)氣設(she)備提(ti)前(qian)維(wei)保(bao)、在(zai)線監(jian)控,提(ti)高(gao)電(dian)氣設(she)備的可靠性、提(ti)高(gao)工(gong)作(zuo)效率(lv);
③實現配(pei)電室(shi)的遙(yao)信、遙(yao)控,打(da)造(zao)遠(yuan)程控制(zhi)監(jian)控的配電(dian)室(shi),並(bing)且*地監控配電(dian)室(shi)。
3智(zhi)能化(hua)配電(dian)室的實現
智(zhi)能化(hua)配電(dian)室系(xi)統(tong)由(you)3部(bu)分(fen)構(gou)成(cheng),分(fen)別是智能供(gong)配電(dian)系(xi)統(tong)、視(shi)頻(pin)、音頻監(jian)測控制(zhi)系(xi)統(tong)和停送電(dian)自(zi)動控制(zhi)系(xi)統(tong)。
3.1智(zhi)能供(gong)配電(dian)系(xi)統(tong)
地面生(sheng)產系(xi)統(tong)主要(yao)有(you)6kV高(gao)壓(ya)用(yong)電(dian)設備及380V及(ji)以(yi)下低(di)壓(ya)用(yong)電(dian)設備,因此(ci)地面生(sheng)產系(xi)統(tong)配(pei)電(dian)室(shi)由6kV和380V配電櫃構(gou)成(cheng)。高壓配(pei)電(dian)櫃主要(yao)由真(zhen)空(kong)斷(duan)路(lu)器(qi)櫃、PT櫃(gui)、真(zhen)空(kong)接(jie)觸器(qi)櫃構(gou)成(cheng)。地面生(sheng)產系(xi)統(tong)配(pei)電(dian)室(shi)真空(kong)斷(duan)路(lu)器(qi)櫃、PT櫃(gui)、真(zhen)空(kong)接(jie)觸器(qi)櫃采用(yong)戶(hu)內(nei)小(xiao)車式(shi)高(gao)壓開關(guan)設備,並(bing)配(pei)有(you)微(wei)電(dian)腦(nao)綜合保護(hu)裝(zhuang)置(zhi)和對(dui)應(ying)的監測(ce)傳感設施(shi)。微電(dian)腦(nao)綜(zong)合(he)保護(hu)裝(zhuang)置(zhi)預留(liu)有(you)RS-485通(tong)信(xin)接(jie)口(kou)和以(yi)太(tai)網(wang)通(tong)信(xin)接(jie)口(kou),通(tong)過以(yi)太(tai)網(wang)通(tong)信(xin)接(jie)口(kou),遠(yuan)程查看(kan)報警(jing)、故障和其他相(xiang)關(guan)記錄(lu),記錄(lu)配電設備運行信息,可以(yi)實現對(dui)配(pei)電(dian)設(she)備運行遙(yao)信、遙(yao)控功能,但(dan)缺少對(dui)高(gao)壓(ya)櫃(gui)內(nei)環(huan)境(jing)的監測(ce)。對(dui)於(yu)6kV的高壓(ya)櫃(gui),長時間運行時真空(kong)斷(duan)路(lu)器(qi)或(huo)真空(kong)接(jie)觸器(qi)主觸頭(tou)和母排連接(jie)部(bu)位(wei)會(hui)因老(lao)化(hua)導致(zhi)接(jie)觸電(dian)阻變大而發熱。6kV高壓開關(guan)櫃運(yun)行時是封閉(bi)的,運行時沒(mei)法(fa)打(da)開檢查,觸頭(tou)位置(zhi)又(you)不便(bian)於(yu)檢查,很難(nan)監(jian)測主觸頭(tou)發熱位置(zhi)的溫度(du),因此(ci)很(hen)容易(yi)導致(zhi)事(shi)故(gu)的發生(sheng)。因此(ci),需(xu)要(yao)對(dui)真(zhen)空(kong)斷(duan)路(lu)器(qi)或(huo)真空(kong)接(jie)觸器(qi)進(jin)、出的6個主觸頭(tou)位置(zhi)進(jin)行在線溫(wen)度(du)監測(ce),並(bing)且設(she)置(zhi)報警(jing)溫度(du)來保證高壓(ya)系(xi)統(tong)的安全(quan)運行。
作為地面生(sheng)產系(xi)統(tong)配(pei)電(dian)系(xi)統(tong)的末端單元的低(di)壓(ya)配電櫃,影響著地面生(sheng)產系(xi)統(tong)設(she)備的正常運(yun)行。目(mu)前(qian)地面生(sheng)產系(xi)統(tong)低(di)壓(ya)配電系(xi)統(tong)中,低(di)壓(ya)電氣設(she)備回路(lu)只(zhi)有(you)PLC控制(zhi)器(qi)的輸入(ru)端反饋(kui)狀(zhuang)態正常信(xin)號和有(you)故(gu)障信(xin)號等(deng)開關(guan)量信號(hao)。出(chu)現故(gu)障時,電氣設(she)備主回路依(yi)據PLC輸入(ru)信號(hao)終止主回路運(yun)行,這(zhe)些故障由(you)電工(gong)根(gen)據工(gong)作(zuo)經驗(yan)和綜合保護(hu)裝(zhuang)置(zhi)的報警(jing)或(huo)提(ti)示(shi)來預測(ce)故(gu)障原因,然(ran)後逐個(ge)排(pai)除(chu)故障。
低(di)壓(ya)配電櫃目(mu)前(qian)還(hai)存(cun)在(zai)以(yi)下問題:
①地面生(sheng)產系(xi)統(tong)使(shi)用(yong)的低(di)壓(ya)開關(guan)櫃的綜保(bao)反饋(kui)的故障信(xin)號非(fei)常單(dan)壹,想(xiang)通過反饋(kui)信(xin)號排(pai)除故障難(nan)度(du)大,用(yong)時長,影響設備正常運(yun)行;
②由於(yu)電氣故(gu)障的隱蔽性(xing)和故障點(dian)不容易(yi)被(bei)發現,平(ping)時需(xu)要(yao)投入(ru)大量的人力來檢查保養低(di)壓(ya)電氣櫃(gui);
③缺少對(dui)隱(yin)蔽故(gu)障的檢查和判斷(duan),如(ru)果主回路發生(sheng)故(gu)障,有(you)可(ke)能會(hui)對(dui)電(dian)氣設(she)備造成(cheng)無(wu)法(fa)恢復(fu)的破壞(huai),造(zao)成壹定的經濟損(sun)失(shi),甚至會對(dui)安(an)全(quan)生(sheng)產造(zao)成(cheng)影響;
④由於(yu)沒(mei)有(you)準(zhun)確(que)反饋(kui)故(gu)障點(dian),所以(yi)排(pai)除故障要(yao)靠維修(xiu)電(dian)工(gong)根(gen)據工(gong)作(zuo)經驗(yan)來排除故障,用(yong)時過長,影響生(sheng)產。智(zhi)能化(hua)供配(pei)電系(xi)統(tong)的基本(ben)組成(cheng)部(bu)分(fen)是智能化(hua)的配電(dian)櫃(gui)。
目(mu)前(qian)使(shi)用(yong)的配電(dian)櫃(gui)和智能化(hua)的配電(dian)櫃(gui)相比,智(zhi)能化(hua)的配電(dian)櫃(gui)在配電(dian)櫃上(shang)使(shi)用(yong)了(le)有(you)通(tong)信(xin)功能的綜合(he)保(bao)護(hu)裝(zhuang)置(zhi)和檢測儀表(biao);對(dui)高(gao)、低(di)壓(ya)斷(duan)路(lu)器(qi)實行遠(yuan)程停(ting)送電(dian)操作(zuo);電(dian)動機電源(yuan)櫃(gui)的綜合(he)保(bao)護(hu)裝(zhuang)置(zhi)增(zeng)加(jia)其(qi)他的故障保(bao)存(cun)和記錄(lu)功能、監(jian)測和報警(jing)提(ti)示(shi)功能,並(bing)將(jiang)所有(you)的數(shu)據傳送到(dao)通信網(wang)絡(luo)記錄(lu)和保存(cun)。智(zhi)能化(hua)的配電(dian)櫃(gui)具有(you)完(wan)整(zheng)的監測(ce)控制(zhi)系(xi)統(tong),能為供配電(dian)系(xi)統(tong)提(ti)供(gong)有(you)效(xiao)管(guan)理和風險(xian)報(bao)警(jing);智能化(hua)的配電(dian)櫃(gui)的報警(jing)功能,可(ke)以(yi)提(ti)前(qian)發現隱(yin)蔽的隱患(huan);智(zhi)能配(pei)電櫃(gui)還有(you)精(jing)度(du)高、量程寬、高性能、高(gao)度(du)集成(cheng)化的特(te)點。智(zhi)能化(hua)的配電(dian)櫃(gui)還對(dui)斷(duan)路(lu)器(qi)的操作(zuo)次(ci)數(shu)、接(jie)觸器(qi)動作次(ci)數(shu)、主觸頭(tou)溫度(du)、電氣設(she)備的運行時間進(jin)行監測(ce),對(dui)報(bao)警(jing)和故障進(jin)行分(fen)析(xi)維護(hu),還(hai)能對(dui)電(dian)氣主回路的運行狀態進(jin)行監測(ce),還(hai)能在(zai)線監(jian)控低(di)壓(ya)抽(chou)屜(ti)櫃(gui)的工(gong)作(zuo)環(huan)境(jing)。由於(yu)智能化(hua)的配電(dian)櫃(gui)上(shang)的監測(ce)儀器(qi)、儀表(biao)接(jie)入(ru)通信(xin)網(wang)絡(luo),實現了(le)采集、修(xiu)改(gai)電(dian)氣設(she)備參(can)數(shu),實現了(le)現場(chang)無人(ren)操作(zuo)、集中管(guan)理,遠(yuan)程操作(zuo)。
3.2視(shi)頻(pin)、音頻監(jian)測控制(zhi)系(xi)統(tong)
視(shi)頻(pin)、音頻監(jian)測控制(zhi)系(xi)統(tong)對(dui)智(zhi)能化(hua)配電(dian)室進(jin)行在線監(jian)測(ce)監控電氣設(she)備運行的數(shu)據;視(shi)頻(pin)、音頻監(jian)測控制(zhi)系(xi)統(tong)則(ze)是對(dui)配(pei)電(dian)室(shi)環(huan)境(jing)監控的補充(chong)。要(yao)想(xiang)對(dui)配(pei)電(dian)室(shi)環(huan)境(jing)進(jin)行在線監(jian)測(ce)監控就要(yao)在配(pei)電(dian)室(shi)增(zeng)加(jia)攝(she)像(xiang)頭(tou)或(huo)加(jia)裝(zhuang)可(ke)移(yi)動的攝像(xiang)頭(tou),實現配(pei)電櫃(gui)和監視(shi)畫(hua)面聯(lian)動。當出現報(bao)警(jing)或(huo)故障時時間鎖定、監(jian)視(shi)、查看(kan)有(you)問題的配電(dian)櫃(gui),進(jin)行在線監(jian)視(shi),保(bao)證(zheng)設備和人員的安全(quan),真正實現智(zhi)能化(hua)配電(dian)室的“遙(yao)視(shi)"。
3.3無(wu)人(ren)操作(zuo)的停送電(dian)自(zi)動控制(zhi)系(xi)統(tong)
無(wu)人(ren)操作(zuo)的停送電(dian)自(zi)動控制(zhi)系(xi)統(tong)是以(yi)計(ji)算(suan)機或(huo)其他終端設備為基礎的現場(chang)無人(ren)操作(zuo)、完(wan)成停送電(dian)作業的控制(zhi)與(yu)監測(ce)的系(xi)統(tong),主要(yao)組成(cheng)部(bu)分(fen)是操作(zuo)軟件、計(ji)算(suan)機、視(shi)頻(pin)監(jian)控和通信設施(shi);無(wu)人(ren)操作(zuo)的停送電(dian)自(zi)動控制(zhi)系(xi)統(tong)通(tong)過通信(xin)網(wang)絡(luo)遠(yuan)程控制(zhi)智(zhi)能停(ting)送電(dian)機器(qi)人對(dui)高(gao)、低(di)壓(ya)開關(guan)設備進(jin)行停電(dian)、送電(dian)操作(zuo),*替代傳統(tong)的專職(zhi)電(dian)工(gong)進(jin)行停送電(dian)操作(zuo)工(gong)作(zuo),消(xiao)除了停送電(dian)作業的安全(quan)隱患(huan),保(bao)證(zheng)了(le)停送電(dian)作業人員(yuan)的人身(shen)安(an)全(quan),該系(xi)統(tong)可(ke)以(yi)根(gen)據生(sheng)產現場(chang)的需(xu)求(qiu)實現對(dui)高(gao)低(di)壓(ya)配電櫃進(jin)行準確(que)無(wu)誤(wu)的停送電(dian)操作(zuo)和監視(shi)。
4安(an)科瑞(rui)配電(dian)室(shi)環(huan)境(jing)監控系(xi)統(tong)的介紹(shao)與(yu)選型
4.1簡介
安(an)科瑞(rui)電氣股(gu)份有(you)限(xian)公(gong)司(si)根據配(pei)電室(shi)實際情況,結合多年的變電站(zhan)和配電室的運行管理經驗(yan),自(zi)主研發了安科瑞(rui)配電(dian)室(shi)綜(zong)合監控系(xi)統(tong),實現了(le)智能開關(guan)櫃運(yun)行監控、高壓(ya)開關(guan)櫃帶(dai)電(dian)顯(xian)示(shi)、電流(liu)電壓等(deng)負(fu)載(zai)運行監控、母線測(ce)溫(wen)監測(ce)、電(dian)纜(lan)測(ce)溫監測(ce)、環(huan)境(jing)監測、有(you)害(hai)氣體(ti)監(jian)測(ce)、安(an)防監控、采暖(nuan)通(tong)風(feng)、門(men)禁、燈(deng)光、風(feng)機(ji)、除(chu)濕機、空(kong)調控制(zhi)等(deng)功能。實現動力環(huan)境(jing)各(ge)數(shu)據的檢測(ce)與(yu)設備控制(zhi),實現動力環(huan)境(jing)優化,避免(mian)運(yun)行環(huan)境(jing)的失控導致(zhi)配(pei)電(dian)設(she)備運行故障,保(bao)證維(wei)護(hu)人(ren)員(yuan),延長設備使(shi)用(yong)壽(shou)命(ming),減少配(pei)電室(shi)粗放(fang)式(shi)管理導致(zhi)成(cheng)本(ben)過高,同(tong)時實現配(pei)電動力環(huan)境(jing)的分(fen)布式(shi)遠(yuan)程管(guan)理。
4.2系(xi)統(tong)功能
4.2.1通(tong)信管(guan)理
安科瑞(rui)智能配(pei)電室(shi)綜合(he)監(jian)控系(xi)統(tong)可(ke)以(yi)完(wan)成對(dui)整(zheng)個(ge)配(pei)電室範(fan)圍(wei)內(nei)的通信(xin)設(she)備進(jin)行管理、添加(jia)、刪除、控制(zhi)和數(shu)據的實時監測。
4.2.2實時監測
安科瑞(rui)智能配(pei)電室(shi)綜合(he)監(jian)控系(xi)統(tong)人(ren)機(ji)界面友(you)好,能夠(gou)顯示(shi)配電(dian)室(shi)設備的運行狀態,實時監測配電(dian)室(shi)環(huan)境(jing)參(can)數(shu)信息,如視(shi)頻(pin)、溫(wen)度(du)、濕度(du)、漏(lou)水(shui)/水(shui)浸(jin)、水(shui)位(wei)、有(you)害(hai)氣體(ti)和電參(can)量等。實時顯示有(you)關(guan)故障、告(gao)警(jing)等信(xin)息。
4.2.3數(shu)據查詢
在(zai)人機(ji)界面中,可(ke)以(yi)直(zhi)接(jie)查看(kan)配電(dian)室(shi)個(ge)設備的運行數(shu)據。
4.2.4曲(qu)線查詢
在(zai)曲線查詢界面,可以(yi)直(zhi)接(jie)查看(kan)遙(yao)測參(can)量曲線,包(bao)括(kuo)溫度(du)、濕度(du)、水(shui)位(wei)、有(you)害(hai)氣體(ti)、電(dian)壓(ya)、電(dian)流等曲線。
4.2.5運(yun)行報表(biao)
查詢配(pei)電室(shi)內(nei)設備的運行數(shu)據報(bao)表,包(bao)括(kuo)日報(bao)表、月報表、年報表(biao)和查詢報(bao)表等(deng)。
4.2.6實時告(gao)警(jing)
安科瑞(rui)智能配(pei)電室(shi)綜合(he)監(jian)控系(xi)統(tong)具(ju)有(you)實時告(gao)警(jing)功能,系(xi)統(tong)能夠(gou)對(dui)配(pei)電(dian)室(shi)溫度(du)、濕度(du)、有(you)害(hai)氣體(ti)、設(she)備故障或(huo)通信(xin)故(gu)障等(deng)事件發出告(gao)警(jing)。告(gao)警(jing)如右圖(tu)所示(shi):
4.2.7歷史(shi)事件查詢
安(an)科瑞(rui)智能配(pei)電室(shi)綜合(he)監(jian)控系(xi)統(tong)能夠(gou)對(dui)產生(sheng)的所有(you)事(shi)件記錄(lu)進(jin)行存(cun)儲(chu)和管理,方便(bian)用(yong)戶(hu)對(dui)系(xi)統(tong)事(shi)件和進(jin)行歷史(shi)追溯、查詢統(tong)計、事(shi)故(gu)分(fen)析(xi)。
4.2.8用(yong)戶(hu)權限(xian)管理
為保障系(xi)統(tong)穩定(ding)運行,設置(zhi)了用(yong)戶(hu)權限(xian)管理功能。通(tong)過用(yong)戶(hu)權限(xian)管理能夠(gou)防止未經的操作(zuo)(如(ru)遙(yao)控的操作(zuo),數(shu)據庫(ku)修(xiu)改(gai)等(deng))。可以(yi)定(ding)義不同(tong)級別(bie)用(yong)戶(hu)的登(deng)錄(lu)名、密碼及(ji)操作(zuo)權限(xian),為系(xi)統(tong)運(yun)行、維護(hu)、管(guan)理提(ti)供(gong)可(ke)靠的保障。
4.2.9網(wang)絡(luo)拓(tuo)撲(pu)圖(tu)
安科瑞(rui)智能配(pei)電室(shi)綜合(he)監(jian)控系(xi)統(tong)支(zhi)持(chi)實時監視(shi)接(jie)入(ru)系(xi)統(tong)的各(ge)設(she)備的通信(xin)狀(zhuang)態,能夠(gou)完整(zheng)的顯示(shi)整(zheng)個系(xi)統(tong)網(wang)絡(luo)結構(gou)。可(ke)在線診(zhen)斷(duan)設(she)備通信(xin)狀(zhuang)態,發生(sheng)網(wang)絡(luo)異(yi)常時能自(zi)動在界面上(shang)顯示故(gu)障設(she)備或(huo)元件及(ji)其(qi)故障部(bu)位(wei)。
4.2.10遙(yao)控操作(zuo)
安(an)科瑞(rui)智能配(pei)電室(shi)綜合(he)監(jian)控系(xi)統(tong)可(ke)以(yi)對(dui)整(zheng)個(ge)配(pei)電系(xi)統(tong)範(fan)圍(wei)內(nei)的設備進(jin)行遠(yuan)程遙(yao)控操作(zuo)。
4.3Acrel-2000E/B配(pei)電室環(huan)境(jing)監控系(xi)統(tong)推(tui)薦(jian)配(pei)置(zhi)選型(xing)
5結語(yu)
通(tong)過對(dui)供(gong)配(pei)電(dian)系(xi)統(tong)的電氣元件增(zeng)設(she)通信功能,完(wan)善供配(pei)電設(she)備數(shu)據監(jian)控,實現配(pei)電室(shi)的智能化(hua)、信息化;通(tong)過無人(ren)操作(zuo)的停送電(dian)管理系(xi)統(tong)集控操作(zuo)人(ren)員與現場(chang)配電(dian)室內(nei)配電(dian)櫃(gui)進(jin)行通信(xin),實現現場(chang)無人(ren)操作(zuo)的遠(yuan)程停(ting)送電(dian)作業,真正實現無(wu)人則(ze)安的停送電(dian)模式。
參(can)考(kao)文獻(xian)
[1] 衛(wei)薇(wei).智能化(hua)配電(dian)生(sheng)產管(guan)理系(xi)統(tong)的應(ying)用(yong)研(yan)究(jiu)[J].貴(gui)州電力技術(shu),2015,18(06)
[2]賽喜(xi)雅拉圖(tu).地面生(sheng)產系(xi)統(tong)智(zhi)能化(hua)配電(dian)室
[3] 安(an)科瑞(rui)Acrel-2000EB配電(dian)室(shi)綜(zong)合監控系(xi)統(tong)2020.04版